Mr. Bernard P. Orlan April 10, 2002 Respirable Particulate Assessment Page 3 Stuvvesant High School (M477') ATC Project No. 15-19125-0246
The Dust Trak® detects volatile aerosol particles that are not recovered by the gravimetric method. The PM, 5 concentrations measured by the Dust Trak® were generally close to those measured with the MEM® in this set of results. On March 11-12 and March 19-20, the Dust Trak® measurements were approximately half the gravimetric results. These are the exceptions to the pattern that has been so far observed. The,Dust Trak® results from the other four days are greater than the MEM® results by <1% to 20%.
The calibration factor of the Dust Trak® was electronically reset from 1.00 to 0.34 and the reset instrument was put in place beginning with the February 25-26 sampling period. The adjustment was made, based on previous side-by-side sampling results, to see if the Dust Trak® data would more closely approximate the gravimetric results. This was reset again to 0.5 on March 4, 2002. The results obtained show that this may be a reasonable conversion factor although there still will be differences between the gravimetric method and the Dust Trak®.
Results by both methods on all eight days were below the EPA NPAAQS of 65 ug/m’ and the EPA recommended level of 40 ug/m\ -3
CONCLUSION
Side-by-side sampling conducted to date does not indicate a predictable conversion factor for results from these two instruments. The Dust Trak® can provide instantaneous readings that may be used to demonstrate trends in PM. , concentrations but it should not be used to determine compliance with EPA standards. The results are subject to misinterpretation.
Sample results obtained by both instruments were below both the EPA NPAAQS for PM2 5 of 65 ug/m^ (24-hour average) and the EPA recommended level of 40 ug/m\
It is our pleasure to provide these indoor air consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353- 8280, extension 212.
Sincerely, ATC ASSOCL4TES INC.
James R. Cohn, CIH, CSP Regional Manager, Industrial Hygiene Division
Attachments
CITY_21MC100_002896804
NYC-WTC_000401080
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000401062
April 1, 2002 letter presenting respirable particulate monitoring at a NYC school site.
11 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312462
Memo from ATC to NYC BOE about a respirable particulate IAQ study at a high school.
11 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000308767
ATC report on six-date respirable particulate monitoring at the school building.
11 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000308751
February–March 2002 IAQ monitoring at the named high school to assess respirable particulates.
11 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312475
April 1, 2002 letter from ATC regarding respirable particulate IAQ monitoring at a NYC school.
11 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340812
Air quality sampling report prior to school resumption.
8 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312378
ATC respirable particulate sampling report for Stuyvesant High School (Mar–Apr 2002).
9 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326949
Respirable particulate assessments conducted at PS 89M prior to class resumption.
8 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329663
Respirable particulate sampling at PS 89M conducted Aug 17, 2002 for DOE indoor air quality.
8 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328008
Lab report for respirable particulate sampling conducted December 16–17, 2002.
8 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000406323
April–May 2002 particulate sampling report for indoor air quality at Stuyvesant HS.
9 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340808
Particulate sampling report for DOE school building air quality.
8 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000308767
ATC report on six-date respirable particulate monitoring at the school building.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401062
April 1, 2002 letter presenting respirable particulate monitoring at a NYC school site.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000308751
February–March 2002 IAQ monitoring at the named high school to assess respirable particulates.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000223635
Table comparing 24-hour average PM2.5 concentrations measured by Dust Trak and MEM devices at P.S. 150M during April 2002.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000223635
Table comparing 24-hour average PM2.5 concentrations measured by Dust Trak and MEM devices at P.S. 150M during April 2002.
Similarity score 0.961 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106330
Letter reporting asbestos testing results for air and dust at Borough of Manhattan Community College in February 2002.
Similarity score 0.958 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000401062
April 1, 2002 letter presenting respirable particulate monitoring at a NYC school site.
Similar indexed content
NYC-WTC_000312462
Memo from ATC to NYC BOE about a respirable particulate IAQ study at a high school.
Similar indexed content
ATC report on six-date respirable particulate monitoring at the school building.
Similar indexed content
NYC-WTC_000308751
February–March 2002 IAQ monitoring at the named high school to assess respirable particulates.
Similar indexed content
NYC-WTC_000312475
April 1, 2002 letter from ATC regarding respirable particulate IAQ monitoring at a NYC school.
Similar indexed content