NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 24 pages

Lab report, Pace Analytical, 24 pages

Machine-extracted title · confidence 28%

Pace Analytical lab report, 24 pages, Project [name], ATC 19125-0246; lab analysis details.

NYC-WTC_000400801–000400824
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 ‘ace Analyticar www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Minneapolis, MN 55414 Phone: 612.607.1700 Fax: 612.607.6444

PROJECT: PCDD/PCDF ANALYSES DATE: February 1 2, 2002

PAGE: 7 REPORT NO: 02-1053263

RESULTS

The results from.the analyses are presented in the following:

s Appendix A - Documentation ^4^ppendix B - PCDD/PCDF Analysis Results

> DISCUSSION

The recoveries of the isotopically-labeled PCDD/PCDF internal standards in the sample extracts ranged from 39-92% and indicate a level of efficiency through the extraction and enrichment steps that is considered typical for this matrix. With the exception of one standard, all of the internal standard recoveries for the field samples were within the target limits for this method. However, since the quantifications of the native 2,3,7,8-substituted isomers were based on isotope dilution, the data were automatically corrected for variation in recovery and accurate values were obtained.

The response factor for the labeled OCDD internal standard in the end of shift calibration standard \y: was outside the target range for this method. The response factors from the beginning and end calibrations were averaged to provide an accurate value for this isomer, as described in the method. The affected points are flagged "*" on the data summary sheets.

A laboratory method blank was prepared and analyzed with the sample batch as part of our routine quality control procedures. The results, found at the beginning of Appendix B, show the blank to be free of PCDDs and PCDFs at the reported detection limits. This indicates that the sample i. preparation procedures did hot significantly impact the results of the field sampleideterminations.

l; A laboratory spike sample was also prepared with each sample batch by extracting a clean wipe that had been fortified with native standard materials. Unfortunately, the native analytes were not added to the laboratory spikes prepared with the samples. Therefore, the results from the spikes immediately preceding and following this sample set have been included. Since the samples are 6 spiked with labeled standards prior to extraction, internal standard recoveries suggest that accurate results were obtained. The results, found' at the end of Appendix B, show that the spiked native. p compounds were recovered at 100-145%. It should be noted that the native standards for one of ' the spike samples were recovered slightly above the target limits for this method and are flagged "P" on the data summary sheet. •U;- - • ' , .

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

CITY_2IMCl0 0_0 0 0 4 9 0 813 NYC-WTC_000400808

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000400808Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000400775

Pace Analytical report with 23 pages; chemistry/NELAC standards; project ID partially visible.

Similar indexed content

NYC-WTC_000400723

PACE lab report; 30 pages, NELAC standards, project 19125-0246.

Similar indexed content

PCDD/PCDF lab analysis results, Jan 2002

NYC-WTC_000226877

Pace Analytical laboratory report detailing polychlorinated dibenzo-p-dioxin and dibenzofuran levels in samples from a NYC school.

Similar indexed content

Compare copies and versions →