NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 14 pages

PCDD/PCDF level determination, ATC, NY

Machine-extracted title · confidence 31%

Report of PCDD/PCDF determinations for ATC project; laboratory details and client info on file.

NYC-WTC_000300414–000300427
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 'ace Analyticar Minneapolis. MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444

PROJECT: PCDD/PCDF ANALYSES DATE: March 6, 2002

PAGE: 7 REPORT NO: 02-1053890

RESULTS

The results from the analyses are presented in the following:

Appendix A - Documentation Appendix B - PCDD/PCDF Analysis Results

DISCUSSION

The recoveries of the isotopically-labeled PCDD/PCDF internal standards in the sample extracts ranged from 31-89% and indicate a level of efficiency through the extraction and enrichment steps that is considered typical to somewhat low for this matrix. With the exception of two points, the internal standard recoveries for the field samples were within the target limits for this method. Also, since the quantifications of the native 2,3,7,8-substituted isomers v\/ere based on isotope dilution, the data were automatically corrected for variation in recovery and accurate values were obtained.

One of the end of shift calibration analyses associated with these samples exhibited a response factor for ^2Ci2-2,3,7,8-TCDF that was outside the target range of the method. The response factors from the beginning and ending calibrations were averaged to provide an accurate value for this isomer, as described in the method. The affected points are flagged "*" on the data summary sheets.

A laboratory method blank was prepared and analyzed with the sample batch as part of our routine quality control procedures. The results, found at the beginning of Appendix B, show the blank to be free of PCDDs and PCDFs at the reporting limits. This indicates that the sample processing procedures did not significantly impact the results of the analyses.

A laboratory spike sample was also prepared with the sample batch by extracting a clean wipe that had been fortified with native standard materials. The results, found at the end of Appendix B, show that the spiked native compounds were recovered at 91-107%. This indicates a high degree of accuracy for these determinations.

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

nphf CITY_21MC100_0 03096957

NYC-WTC_000300421

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000300421Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000382417

PACE report: PCDD/PCDF levels for ATC project at 104 East 25th Street.

Similar indexed content

NYC-WTC_000348993

Determination of PCDD/PCDF levels for project: World Trade Center.

Similar indexed content

NYC-WTC_000326628

Analytical lab report for PCDDs & PCDFs; city file reference.

Similar indexed content

Compare copies and versions →