i /•X' Pace Analytical Services, Inc. 1700 Elm Street. Suite 200

•f ^ceAnalyticar : : www.pacelabs.coni REPORT OF: CHEMICAL ANALYSES Minneapolis, MN 55414 Phone: 612.6O7J70O Fax: 612.607.6444

' PROJECT: PCDD/PCDF ANALYSES DATE: January 9, 2002

PAGE: 6 ■ - ■* •• REPORT NO: 01-1052541

J Quality Control for PCDD/PCDF Analyses RI '/"kF' ' ' " k The performance of the sample processing steps and the instrumentation are monitored on a routine basis/-The procedures and criteria are summarized below.

F One method blank and one laboratory spike sample are typically prepared with each ten samples of atj^y/given matrix. Recoveries of the native PCDD/PCDF analytes in the laboratory spike samples H^g^herally range from 70 to 130%. Recoveries of selected analytes outside this range do not invalidate the data but provide information, which is used by the laboratory to monitor recovery trends and to assure optimization of the method.

I internal standards are spiked into each sample prior to extraction in order to monitor the level of 4 recovery, which is achieved for each individual sample. Acceptable recoveries range from 40 to iCn 135 percent for the internal standards unless a deviation is due to variation in instrument response cL as a result of analytical interferences. »' R The resolution of the mass spectrometer is verified prior to each analysis to be 10,000 or greater. Hardcopies of the reference peaks are printed at the beginning and end of each analysis day. The resolving power of the DB-5MS chromatographic column is checked daily by analyzing a standard solution containing 2,3,7,8-TCDD and the adjacent TCDD isomers. The DB-225 column resolution is checked daily by analyzing a standard solution containing 2,3,7,8-TCDF and the adjacent TCDF isomers. Acceptable performance is achieved when 2,3,7,8-TCDD or 2,3,7,8-TCDF is resolved II from the adjacent isomers by a valley of 25% or less. The group times for the selected-ion­ monitoring data acquisitions are also checked daily by analyzing the column performance mix ■ j which has been modified to contain the first and last eluting isomers of each congener class. In Lii this way one is assured of collecting data representative of the total PCDD/PCDF content and that . the 2,3,7,8-substituted isomers are suitably resolved.

Initial calibrations are generated by analyzing standard solutions (see Table 4) containing target native and labeled PCDD/PCDF compounds. Response factors are calculated and averaged for 0 each compound. These averages are used for quantification and for comparison to the daily @ continuing calibration. The relative standard deviation for each native compound must be 20% or less (30% or less for the labeled compounds) as specified in Method 8290. A continuing ■j calibration standard is analyzed at the beginning and end of each 1 2-hour shift on days when initial calibrations are not performed. The initial calibration is considered to be valid when the response factors from the continuing calibration analysis fall to within the ranges specified in Method 8290. ■ i ■ .

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in lull, without the written consent of Pace Analytical Services, Inc.

CITY_21MC100_002896281

NYC-WTC_000400729

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000400729Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000400775

Pace Analytical report with 23 pages; chemistry/NELAC standards; project ID partially visible.

Similar indexed content

NYC-WTC_000400801

Pace Analytical lab report, 24 pages, Project [name], ATC 19125-0246; lab analysis details.

Similar indexed content

PCDD/PCDF lab analysis results, Jan 2002

NYC-WTC_000226877

Pace Analytical laboratory report detailing polychlorinated dibenzo-p-dioxin and dibenzofuran levels in samples from a NYC school.

Similar indexed content

Compare copies and versions →