NYC-WTC_000245355
ATC Associates IAQ measurements collected for the NYC Board of Education at P.S. 89M.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Indoor air quality measurements collected for BOE at PS 89M.
NYC-WTC_000400606–000400609OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan January 25, 2002 Indoor Air Quality Assessment Page 3 P. S. 89M ATC Project No. 15-19125-0297
Real-Time Environmental Measurements
ATC collected eighty (80) sets of real-time environmental measurements consisting of seventy- four (74) from inside the school building and six (6) outdoors. All five floors of the school were surveyed. These results are described below.
Field data sheets are found in Attachment 1. Readings began at 8:00 A.M. and concluded after 2:05 P.M.
Temperature
Indoor dry bulb temperature measurements ranged from 62.0 °F to 72.5 °F. Seventeen (17) measurements were below the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). The outdoor temperature measurements ranged from 50.0 to 53.9 °F.
Relative Humidity
The relative humidity indoors ranged from 37.0 percent to 66.7 percent. Three (3) measurements were above the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity ranged from 56.7 to 66.4 percent.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 488 ppm to 534 ppm. One (1) CO2 measurement was above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (background) CO2 concentrations ranged from 488 to 534 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1234 ppm (background level + 700 ppm). The highest CO2 reading was found in room 402. At the time of ATC’s assessment, this room was occupied by approximately thirty (30) people. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration. The school building during ATC’s assessment was not occupied.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors were 0-1 ppm for all readings. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentration was 0-1 ppm.
Respirable Particulates (PM2,s)
Respirable particulate concentrations* indoors ranged between 21 pg/m^ to 63 pg/mT All measurements were below the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. The average PM2.5 concentration for the entire school building was approximately 42 pg/m^. This average
CITY_21MC100_002896179
NYC-WTC_000400608
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000245355
ATC Associates IAQ measurements collected for the NYC Board of Education at P.S. 89M.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400618
Report of IAQ measurements at PS 89M for BOE; January 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000384040
ATC IAQ measurements report for PS 89M dated January 24, 2002 to NYC BOE.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000249454
Indoor air quality measurements collected January 23, 2002 at PS 234M.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400153
Indoor air quality measurements report for PS 89M, March 6-7, 2002, ATC.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000396289
ATC IAQ measurements at PS 234M, January 2002.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314706
Indoor air quality measurements at PS 234M, Feb 11, 2002, per BOE request.
11 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274710
ATC report of IAQ measurements conducted March 5, 2002 at PS 89M for NYC BOE.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314875
IAQ measurements collected March 11, 2002 at PS 234M for BOE.
11 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382671
ATC memo documenting IAQ evaluation scope at P.S. 89M.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382100
ATC report on indoor air quality tests at the referenced school for BOE evaluation, Feb 2002.
11 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245367
ATC Associates provides IAQ measurements for P.S. 89M per NYC BOE request.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000400618
Report of IAQ measurements at PS 89M for BOE; January 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400153
Indoor air quality measurements report for PS 89M, March 6-7, 2002, ATC.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274710
ATC report of IAQ measurements conducted March 5, 2002 at PS 89M for NYC BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000384040
ATC IAQ measurements report for PS 89M dated January 24, 2002 to NYC BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383951
ATC Associates reports IAQ measurements conducted March 27, 2002 at P.S. 89M for NYC BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245355
ATC Associates IAQ measurements collected for the NYC Board of Education at P.S. 89M.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000245355
ATC Associates IAQ measurements collected for the NYC Board of Education at P.S. 89M.
Similar indexed content
NYC-WTC_000400618
Report of IAQ measurements at PS 89M for BOE; January 2002.
Similar indexed content
NYC-WTC_000384040
ATC IAQ measurements report for PS 89M dated January 24, 2002 to NYC BOE.
Similar indexed content
NYC-WTC_000249454
Indoor air quality measurements collected January 23, 2002 at PS 234M.
Similar indexed content
NYC-WTC_000400153
Indoor air quality measurements report for PS 89M, March 6-7, 2002, ATC.
Similar indexed content