Mr. Bernard P. Orlan January 19, 2002 Indoor Air Quality Assessment Page 3 P. S. 89 (Manhattan) ATC ProjectNo. 15-19125-0297
Real-Time Environmental Measurements
ATC collected fifty (50) sets of real-time environmental measurements consisting of fouily-eight (48) from inside the school building and two (2) outdoors from the playground. All five floors of the school were surveyed. These results are described below.
Field data sheets are found in Attachment 1. Readings began at 8:10 A.M. and concluded after 12:35 P.M.
Temperature
Indoor dry bulb temperature measurements ranged from 67.5 °F to 75.1 °F. Six (6) measurements were below and one (1) was above the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). The outdoor temperature measurements at the playground ranged from 41.9 to 42.7 °F.
Relative Humidity
The relative humidity indoors ranged from 15.4 percent to 24.3 percent. All measurements were below the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity ranged from 22.6 to 22.9 percent.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 409 ppm to 701 ppm. All CO2 measurements were below the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (background) CO2 concentrations were 433 and 440 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1140 ppm (background level -I- 700 ppm). Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration. The school building during ATC’s assessment was not occupied.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors were 0 ppm for all readings. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentration was 0 ppm.
Respirable Particulates (PM2,5)
Respirable particulate concentrations* indoors ranged between 18 pg/m^ to 32 pig/m^. All measurements were below the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. The average PM2.5 concentration for the entire school building was approximately 24 pg/m^.The outdoor respirable particulate concentration ranged from 35 - 36 pg/m^.
CITY_21MC100_000490563 NYC-WTC_000400565
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000400582
Report of IAQ measurements at PS 89M, NYC BOE building, January 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245312
Indoor air quality measurements at P.S. 89M; January 19, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245331
ATC Associates provides IAQ measurement results for P.S. 89M requested by NYC BOE.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000384021
ATC IAQ measurements collected January 22, 2002 at the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000226873
ATC Associates report on indoor air quality measurements collected at P.S. 89M on January 17, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000384011
ATC IAQ measurements collected January 21, 2002 at the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400572
IAQ report for January 21, 2002 at P.S. 89M with measurement results.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000396271
ATC IAQ measurements at PS 234M for BOE, January 2002.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000226869
Cover letter from ATC Associates to the Board of Education submitting indoor air quality measurement results for PS89M.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245321
ATC Associates reports IAQ measurements at P.S. 89M for NYC BOE, January 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000396261
ATC report of IAQ measurements at PS 234M, January 2002.
11 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236958
Letter from ATC Associates to NYC Board of Education reporting indoor air quality measurements at P.S. 89M collected on January 18, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000245312
Indoor air quality measurements at P.S. 89M; January 19, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400594
Report of indoor air quality measurements at PS 89M for BOE project.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000226873
ATC Associates report on indoor air quality measurements collected at P.S. 89M on January 17, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000384033
ATC report of IAQ measurements collected January 23, 2002 at PS 89M for NYC BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245343
ATC Associates reports IAQ measurements conducted at the referenced school for the NYC BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400582
Report of IAQ measurements at PS 89M, NYC BOE building, January 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000400582
Report of IAQ measurements at PS 89M, NYC BOE building, January 2002.
Similar indexed content
NYC-WTC_000245312
Indoor air quality measurements at P.S. 89M; January 19, 2002.
Similar indexed content
NYC-WTC_000245331
ATC Associates provides IAQ measurement results for P.S. 89M requested by NYC BOE.
Similar indexed content
NYC-WTC_000236958
Letter from ATC Associates to NYC Board of Education reporting indoor air quality measurements at P.S. 89M collected on January 18, 2002.
Similar indexed content
NYC-WTC_000384021
ATC IAQ measurements collected January 22, 2002 at the referenced school.
Similar indexed content