NYC 9/11 Public Portal Document
104 East 25th St
(SATC ASSOCIATES INC.
New York. New York 10010
www.atc-enviro.com
212.353.8280
Fax 212.353.8306
February 26, 2002
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Silica
P. S.89M
ATC Project No. 15-19125-0297
Dear Mr. Orlan:
ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for silica-
containing dust conducted on February 7, 2002 at the referenced school. The New York City
Board of Education (BOE) requested this sampling at the recommendation of Environ Corp., the
consultant to the parents association.
Scope of Work
ATC collected ten (10) samples respirable dust using pre-weighed 37mm PVC filters connected
to size-selective cyclones to remove the larger (non-respirable) particles prior to deposition on the
filters. All samples were collected indoors. The samples were sent to PSC Analytical Services,
Inc., an American Industrial Hygiene Association accredited laboratory in Reading, PA. One
blank filter was also submitted. Silica analysis was performed by x-ray diffraction according to
OSHA Method 142. A copy of the analytical report is attached.
Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists of ATC’s New York City office,
collected the samples.
Results
Silica was found above the limits of detection in one sample. This was Sample #S4-ATC-0207-
89M collected in the Gymnasium. The Occupational Safety and Health Administration (OSHA)
Permissible Exposure Limit (PEL) for silica-containing dust is based on the percent of quartz
(SiO2) found in the dust, the higher the percentage of quartz, the lower the PEL. The formula for
calculating the PEL is found in 29 CFR 1910.1000, Table Z-3. The formula is:
lOmg/m^
%SiO2 + 2
CITY_21MC100_000623957
NYC-WTC_000400350
OCR can misread numbers and units. Confirm readings against the page image before using them.