NYC-WTC_000383877
ATC report of IAQ measurements at P.S. 89M for BOE evaluation.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗IAQ measurements collected at PS 89M for BOE, March 2002.
NYC-WTC_000400256–000400259OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan March 20, 2002 Indoor Air Quality Assessment Page 4 P. S.89M ATC Project No. 15-19125-0297 concentration of 40 ug-m^ for sensitive individuals and children. The outdoor respirable particulate concentration measurements ranged from 38 to 44 pg/m^ with an average of 42 pg/m3. Six (6) of the outdoor measurements were above the EPA recommended guideline for children and sensitive individuals of 40 pg/m^-
* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.
TYOCConcen^rations
TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm.
OBSERVATIONS
During this assessment, ATC noted the following: • The school building was occupied at the time of the assessment. • No smoke odor was detected in the building • The interior of the building appeared clean and free of dust and debris.
FINDINGS
Based on the real-time measurements, the following findings are presented:
1. Concentrations of CO and TVOCs were below applicable standards and guidelines. 2. Three (3) of the indoor measurements for temperature were below the range of 68 to 75°F (at 50 percent relative humidity) as recommended by the ASHRAE Standard 55-1992 during the heating season (wintertime conditions). 3. Forty-three (43) of the indoor measurements for relative humidity were below the ASHRAE- recommended range of 30 to 60 percent for occupant comfort. 4. One (1) of the CO2 indoor measurements was above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. 5. Six (6) of the outdoor respirable particulate measurements were above the EPA recommended guideline for children and sensitive individuals of 40 pg/m^-
It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 211 or 212.
Sincerely, Reviewed bv: Al^ASSOCIATE^^^G^^^ ,
Xiannis Efstathigtu James R. Cohn, CIH, CSP Senior Project Manager Regional Manager Industrial Hygiene Division Attachment
CITY_21MC100_000623841 NYC-WTC_000400259
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000383877
ATC report of IAQ measurements at P.S. 89M for BOE evaluation.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313374
March 19, 2002 IAQ report for PS 89M site measurements.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313390
ATC IAQ measurements at P.S. 89M; measurements on March 21, 2002 for BOE evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400276
ATC IAQ field work for BOE at PS 89M, March 21, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383901
ATC IAQ measurement report for PS 89M building.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383889
ATC report of IAQ measurements collected at PS 89M for BOE evaluation.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400288
BOE IAQ measurements at PS 89M; March 22, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400315
IAQ measurements collected March 26, 2002 for BOE.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383913
ATC IAQ report for P.S. 89M building requested by BOE.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400125
ATC indoor air quality measurements report for PS 89M, Warren Street, March 1, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383700
Memo re: indoor air quality measurements at PS 89M, Feb 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313424
IAQ measurements at PS 89M; BOE requested evaluation, March 27, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000383877
ATC report of IAQ measurements at P.S. 89M for BOE evaluation.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313374
March 19, 2002 IAQ report for PS 89M site measurements.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313656
ATC IAQ measurements at P.S. 89M for May 14, 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313646
ATC IAQ measurements at PS 89M for May 13-14, 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328357
ATC reports IAQ measurements collected mid-May 2002 at PS 89M.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328361
ATC IAQ measurements collected May 14, 2002 at PS 89M for BOE review.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000383877
ATC report of IAQ measurements at P.S. 89M for BOE evaluation.
Similar indexed content
NYC-WTC_000313374
March 19, 2002 IAQ report for PS 89M site measurements.
Similar indexed content
NYC-WTC_000313390
ATC IAQ measurements at P.S. 89M; measurements on March 21, 2002 for BOE evaluation.
Similar indexed content
NYC-WTC_000400276
ATC IAQ field work for BOE at PS 89M, March 21, 2002.
Similar indexed content
NYC-WTC_000383901
ATC IAQ measurement report for PS 89M building.
Similar indexed content