NYC-WTC_000369789
ATC IAQ measurements at PS 89M for BOE; May 2002.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗ATC IAQ measurements at PS 89M for May 13-14, 2002.
NYC-WTC_000313646–000313649OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan May 14, 2002 Indoor Air Quality Assessment Page 4 P. S. 89M ATC Project No. 15-19125-0297 recommended concentration of 40 pg/m^ for sensitive individuals and children. The outdoor respirable particulate concentration measurements ranged frona 29 to 33 pg/m^ with an average of 31 pg/m3.
* rhe measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.
TVOCConcentrations
TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm.
OBSERVATIONS
During this assessment, ATC noted the following: • The school building was occupied at the time of the assessment. • No smoke odor was detected in the building • The interior of the building appeared clean and free of dust and debris.
FINDINGS
Based on the real-time measurements, the following findings are presented: 1. Concentrations of CO and TVOCs were below applicable standards and guidelines. 2. Sixty (60) of the indoor measurements for temperature were below the range of 73 to 79°F (at 50 percent relative humidity) as recommended by the ASHRAE Standard 55-1992 during the summer season. 3. One (1) indoor measurement for relative humidity was above the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. 4. One (1) of the indoor measurements for CO2 was above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. 5. All of the indoor respirable particulate measurements were below the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter or the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children.
It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 211 or 212.
Sincerely, A TC ASSOCIA TES INC. Reviewed bv:
nis Efstathiou James R.tohn, CIH, CSP Senior Project Manager Regional Manager Industrial Hygiene Division
Attachment
CITY_21MC100_0 06739581
NYC-WTC_000313649
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000369789
ATC IAQ measurements at PS 89M for BOE; May 2002.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370061
ATC reports indoor air quality measurements taken June 17, 2002 at PS 89M for BOE evaluation.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313893
ATC IAQ measurements collected June 18, 2002 at PS 89M per BOE request.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313656
ATC IAQ measurements at P.S. 89M for May 14, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328357
ATC reports IAQ measurements collected mid-May 2002 at PS 89M.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370089
ATC IAQ measurements conducted June 20, 2002 at PS 89M for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392840
ATC IAQ report of measurements collected May 13, 2002 at PS 89M for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369765
ATC IAQ measurements at PS 89M for BOE, May 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199006
Cover letter from ATC Associates submitting indoor air quality measurement results for PS89M collected on May 7, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369736
ATC IAQ measurements report for PS 89M, May 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313624
ATC IAQ measurements at P.S. 89M for May 9, 2002, BOE evaluation.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313952
ATC report of IAQ measurements at P.S. 89M, June 24, 2002, requested by NYC BOE.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000313656
ATC IAQ measurements at P.S. 89M for May 14, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392852
ATC IAQ report for May 14, 2002 measurements at PS 89M for BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328357
ATC reports IAQ measurements collected mid-May 2002 at PS 89M.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392840
ATC IAQ report of measurements collected May 13, 2002 at PS 89M for BOE.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369789
ATC IAQ measurements at PS 89M for BOE; May 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313976
ATC report of IAQ measurements at P.S. 89M, June 26, 2002, for air quality assessment.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000369789
ATC IAQ measurements at PS 89M for BOE; May 2002.
Similar indexed content
NYC-WTC_000370061
ATC reports indoor air quality measurements taken June 17, 2002 at PS 89M for BOE evaluation.
Similar indexed content
NYC-WTC_000313893
ATC IAQ measurements collected June 18, 2002 at PS 89M per BOE request.
Similar indexed content
NYC-WTC_000313656
ATC IAQ measurements at P.S. 89M for May 14, 2002.
Similar indexed content
NYC-WTC_000328357
ATC reports IAQ measurements collected mid-May 2002 at PS 89M.
Similar indexed content