NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street-Suite 200
Minneapolis, MN 56414
w Analytical Method 829© Laberatoiry CofstroB Sp’ke ResiuJte
Tel; 612-607-1700
Client - ATC ASSOCIATES
I
Lab Sample ID SPIKE-DUP-1411
Filename F20512A_03 Matrix WIPE
Total Amount Extracted 1 m2 Dilution NA
ICAL Date 05/04/2002 Extracted 05/09/2002
CCal Filename(s) F20512A_01 & F20512A_16 Analyzed 05/12/2002 21:35
Method Blank ID BLANK-1614 Injected By BAL
WatSv© Qg Qm % tntemsi fig'® Pereemit
bom©?® (ng) (ng) Rec, SlaYSjgj’ds Racevery
2,3,7,8-TCDF 0.20 0.21 103 2,3,7,8-TCDF-13C 2.00 78
2,3.7,8-TCDD-13C 2.00 74
1,2,3,7,8-PeCDF-13C 2.00 72
2,3,7,8-TCDD 0.20 0.21 103 2,3,4,7,8-PeCDF-13C 2.00 71
1,2,3,7,8-PeCDD-13C 2.00 70
1,2,3,4,7,8-HxCDF-13C 2.00 100
1,2,3,7,8-PeCDF 1.00 1.04 104 1,2,3,6,7,8-HxCDF-13C 2.00 97
2,3,4,7,8-PeCDF 1.00 1.06 106 2,3,4,6,7,8-HxCDF-13C 2.00 93
1,2,3,7,8,9-HxCDF-13C 2.00 87
1,2,3,4,7,8-HxCDD-13C 2.00 94
1,2,3,7,8-PqCDD 1.00 0.98 98 1,2,3,6.7,8-HxCDD-13C 2.00 94
1,2,3,4,6,7,8-HpCDF-13C 2.00 92
1,2,3,4,7,8,9-HpCDF-13C 2.00 76
1,2,3,4,7,8-HxCDF 1.00 1.03 103 1,2,3,4,6,7,8-HpCDD-13C 2.00 80
1,2,3,6,7,8-HxCDF 1.00 1.03 103 OCDD-13C 4.00 61
2,3,4,6,7,8-HxCDF 1.00 1.06 106
1,2,3,7,8,9-HxCDF 1.00 1.02 102 1,2,3,4-TC0.P-13C 2.00 NA
1,2,3.7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD 1.00 1.06 106 2,3,7,8-TCDD-37CI4 0.20 79
1,2.3,6.7,8-HxCDD 1.00 1.06 106
1,2,3,7,8.9-HxCDD 1.00 1.02 102
1,2,3,4,6,7,8-HpCDF 1.00 1.00 100
1,2,3,4,7,8,9-HpCDF 1.00 0.99 99
1,2,3,4,6,7.8-HpCDD 1.00 1.00 100
OCDF 2.00 2.07 104
OCDD 2.00 2.14 107
Qs = Quantity Spiked
Qm = Quantity Measured
Rec. = Recovery (Expressed as Percent)
P = Recovery outside of target range
X = Background subtracted value
Nn = Value obtained from additional analysis
NA = Not Applicable
’ = See Discussion Report No.... 02-1057192
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_002894516
NYC-WTC_000398271
OCR can misread numbers and units. Confirm readings against the page image before using them.