Pace Analytical Sendees, Inc.
1700 Elm Street-Suite 200
Minneapolis. MN 55414
race Analytical_________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax: 612- 607-6444
Client - ATC ASSOCIATES
Client's Sample ID ATC-0429-150M DX2
Lab Sample ID 103517215
Filename F20513A_08
Injected By MRO
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/29/2002
ICAL Date 05/04/2002 Received 05/07/2002
CCal Filename(s) F20512A_16 a F20513A_14 Extracted 05/09/2002
Method Blank ID BLANK-1614 Analyzed 05/13/2002 14:03
Native Cone EMPC LRL Internal ng's Percent
Isomeirs ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ---- 0.0022 0.00200 I 2,3,7.8-TCDF-13C 2.00 81
Total TCDF ND 0.00200 2,3,7,8-TCDD-13C 2.00 79
1,2,3,7,8-PeCDF-13C 2.00 76
2,3,7,8-TCDD ND 0.00200 2,3,4,7,8-PeCDF-13C 2.00 74
Total TCDD 0.012 0.00200 B 1,2,3,7,8-PeCDD-13C 2.00 74
1,2,3,4,7,8-HxCDF-13C 2.00 104
1,2,3,7,8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 103
2,3.4.7.8-PeCDF ND 0.01000 2,3,4,6.7.8-HxCDF-13C 2.00 98
Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2.00 93
1,2,3,4,7,8-HxCDD-13C 2.00 100
1.2,3,7,8-PeCDD ND 0.01000 1,2.3,6.7,8-HxCDD-13C 2.00 93
Total PeCDD ND 0.01000 1,2,3.4,6,7.8-HpCDF-13C 2.00 103
1,2,3,4,7,8.9-HpCDF-13C 2.00 90
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3.4.6,7,8-HpCDD-13C 2.00 95
1,2,3,6.7,8-HxCDF ND 0.01000 OCDD-13e 4.00 69
2,3.4,6,7,8-HxCDF ND 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1.2,3.7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2,3.7,8-TCDD-37CI4 0.20 88
1,2,3,6,7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0.01000
Total HxCDD ND 0.01000
1,2,3.4,6.7,8-HpCDF ND 0.01000 Total 2,3,7.8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.01000 Equivalence: 0.00036 ng/m2
Total HpCDF 0.020 0.01000 BJ (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.018 0.01000 BJ
Total HpCDD 0.032 0.01000 BJ
OCDF 0.039 0.02000 BJ
OCDD 0.140 0.02000 B
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis “ = See Discussion
Report No.... 02-1057192
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_002894514