Asbestos TEM analysis report, PS 150M

Machine-extracted title · confidence 54%

Asbestos TEM analysis report for PS 150M air samples; AHERA protocol.

NYC-WTC_000397050
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Associates 104 East 25 Street, New York, NY 10010 Phone:(212) 353-8280 Fax; (212) 353-8306

.Attn: .Mr. Bernard Orlan Received: 4/22/02 9:30:00 PM N.Y.C. Board of Education ATC Group#: 7507 28-11 Queens Plaza North Analysis Date: 4/22/02 Long Island City, NY 11101 Fax: (212)475-4122 Phone: (212)477-8941 Project: NYC-BOE PS 150M Project#: 14584-0824 334 Greenwich St., New York, NY. 10013

Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample Volume Analyzed Asb Type(s) O.S/t-5 5/1 (S/cc) (S/mm‘) (S/ccJ Notes

01 1920.00 00450 0 None Detected 0 0 0.0045 <22.24 <0.0045 750 7 -I

02 1920.00 0.0450 0 CHRYSOTILE 1 0 0.0045 22.24 0.0045 7507 -2

03 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7SO7 -3

04 1920.00 0,0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7507 -4

05 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 < 0.0045 '507 -5

06 1912.00 0.0450 0 None Detected 0 0 0.0045 <22.24 0.0045 7507 -6

07 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7507 -

ROMAN PEYSAKHOV^ MICH.AEL A. GORYCKl, Ph D

Analyzed jipproved bv

Disclaimer: The laboraloty is not responsible for data reported in struclures/K, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible tor data reported in structures/mm’ This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be useo to ciairr, product endorsement by NVLAP or any other agency of the U .S. Government. This reports relates only to the samples reported above. Quality control data (including 35% confidence limits and laboratory and analysis' accuracy and precision) is available upon request.

Accreaitec for NVLAP PLM/TEM #101187-0, NY State ELAP #10879

Pa^e ! I)/ I

CITY_21MC100_002919843

NYC-WTC_000397050

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000397050Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →