NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
TM
Analytical
Method 8290 Laboratory Control Spike Results
Tel: 612-607-1700
Fax: 612- 607-6444
Client - ATC
Lab Sample ID SPIKE-DUP-1405
Filename U20506B_01 Matrix WIPE
Total Amount Extracted 1 m2 Dilution NA
iCAL Date 04/16/2002 Extracted 04/30/2002
CCal Filename{s) U20506A_15 & U20506B_15 Analyzed 05/06/2002 21:42
Method Blank ID BLANK-1606 Injected By CVS
Native Qs Qm % internal ng'S Percent
Isomers !ng) (ng) Rec, Standards Added Recovery
2.3,7,8-TCDF c.20 0.21 104 2,3,7,8-TCDF-13C 2.00 79
2,3,7,8-TCDD-13C 2.00 83
1,2,3.7,8-PeCDF-13C 2.00 80
2.3,7,8-TCDD C.20 0.20 98 2,3,4,7,8-PeCDF-13C 2.00 78
1,2,3,7,8-PeCDD-13C 2.00 82
1.2,3,4,7,8-HxCDF-13C 2.00 98
1,2,3,7,8-PeCDF 1.00 1.05 105 1.2,3,6,7,8-HxCDF-13C 2.00 104
2,3,4,7,8-PeCDF 1.00 1.04 104 2,3,4,6,7,8-HxCDF-13C 2.00 98
1,2,3,7,8,9-HxCDF-13C 2.00 98
1.2.3,4,7,8-HxCDD-13C 2.00 95
1,2,3,7,8-PeCDD 1.00 0.96 96 1,2,3,6,7,8-HxCDD-13C 2.00 92
1,2,3,4,6,7,8-HpCDF-13C 2.00 99
1,2,3,4,7,8,9-HpCDF-13C 2.00 99
1,2,3,4,7,8-HxCDF 1.00 1.01 101 1,2,3,4,6,7,8-HpCDD-13C 2.00 99
1,2,3,6,7,8-HxCDF 1.00 1.07 107 OCDD-13C 4.00 101
2,3,4,6,7,8-HxCDF 1.00 1.01 101
1.2.3,7,8,9-HxCDF 1.00 0.97 97 1,2,3,4-TCDD-13C 2.00 NA
1,2,3,7.8.9-HxODD-13C 2.00 NA
1,2,3,4,7,8-HxCDD 1.00 1.00 100 2,3,7,8-TCDD-37CI4 0.20 94
1,2,3,6,7,8-HxCDD 1.00 1.02 102
1,2,3,7,8,9-HxCDD 1.00 1.06 106
1,2,3,4,6,7,8-HpCDF 1.00 0.96 96
1,2,3,4.7,8,9-HpCDF 1.00 0.94 94
1,2,3,4,6,7,8-HpCDD 1.00 0.96 96
OCDF 2.00 1.94 97
OCDD 2.00 1.89 95
Qs = Quantity Spiked
Qm = Quantity Measured
Rec. = Recovery (Expressed as Percent)
P = Recovery outside of target range
X = Background subtracted value
Nn = Value obtained from additional analysis
NA:-. Not Applicable
• = See Discussion Report No.... 02-1056602
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_002919506