Indoor air quality report, High School of Economics, Jun 2002

Machine-extracted title · confidence 42%

ATC IAQ measurements collected June 13, 2002 under BOE directive for IAQ maintenance.

NYC-WTC_000396707–000396710
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan June 14, 2002 Indoor Air Quality Assessment Page 4 H.S. of Economics and Finance (M8331 ATC Project No. 15-19125-0291

TVOC Concentration

TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm.

OBSERVATIONS

During this assessment, ATC noted the following: • The interior of the building appeared clean and free of dust and debris; • The building was occupied at the time of the assessment; • No smoke odor was detected in the building;

FINDINGS

Based on the real-time measurements, the following findings are presented:

1. Indoor concentrations of CO and TVOCs were below applicable standards and guidelines. 2. Sixteen (16) of the indoor measurements for temperature were above and none of the measurements were below the range of 73 °F to 79°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the summer season. 3. All of the indoor measurements for relative humidity were within ASHRAE recommended range of 30 to 60 percent for occupant comfort. 4. Nine (9) of the indoor measurements for CO2 were above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The highest concentration (1311 ppm) was recorded in room 307 around 11:55 AM with 27 occupants. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration. 5. None of the indoor measurements for respirable particulates were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children.

It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, ext 211 or 212.

Sincerely, Reviewed by: /I TC ASSOCIA TES INC.

el Jaydl James R. Cohn, CIH, CSP Senior Project Manager Regional Manager Industrial Hygiene Division Attachment

CITY_21MC100_002891792

NYC-WTC_000396710

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000396710Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000223584

Report of indoor air quality measurements collected at the High School of Economics and Finance on May 15, 2002.

Similar indexed content

NYC-WTC_000259479

ATC IAQ measurements report for May 30, 2002 at the school.

Similar indexed content

NYC-WTC_000385103

ATC IAQ measurements collected June 13, 2002 for BOE at the High School of Economics and Finance.

Similar indexed content

NYC-WTC_000396575

ATC IAQ measurements collected May 17, 2002 for BOE program on maintaining IAQ.

Similar indexed content

Compare copies and versions →