OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 ^aceAnalyticar Minneapolis. MN 554M Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444

PROJECT: PCDD/PCDF ANALYSES DATE: December 20, 2001

PAGE: 2 REPORT NO: 01-1051920

METHODOLOGY (Cont.)

Sample Extraction

Each PUF cartridge was spiked with isotopically-labeled PCDD/PCDF internal standards (Table 1), combined with the filter, and extracted for 18 hours with toluene in a Soxhlet extractor. The extract was quantitatively transferred to a Kuderna Danish concentrator, concentrated, solvent 3 exchanged to hexane, and processed through the analyte enrichment procedures described below.

Analyte Enrichment for PCDD/PCDF Analyses

The extraction procedure often removes a variety of compounds, in addition to the PCDDs and PCDFs, from the sample matrix. Some of these compounds can directly interfere with the analyses J while others can overload the capillary column causing degradation in chromatographic resolution or sensitivity. The analyte enrichment steps described below were used to remove interferences from the extracts.

Each sample extract was diluted to 100 mL with hexane, transferred to a separatory funnel, and 1- washed with IN sodium hydroxide, concentrated sulfuric acid, and aqueous sodiurn chloride (5% a w/v) as needed. The hexane layer was concentrated to 1 mL and quantitatively transferred to a liquid chromatography column containing alternating layers of silica gel, 40% concentrated sulfuric acid on silica gel, and 33% IN sodium hydroxide on silica gel. The column was eluted with 90 nriL 1 of hexane and the entire eluate was collected-and concentrated, under ambient conditions, to a volume of 1 mL.

J Each extract was then fractionated on a liquid chromatography column containing 4 g of activated alumina. The column was eluted with 20 mL of hexane followed by 15 mL of 60% methylene chloride/hexane. The 60% methylene chloride/hexane fraction was concentrated to 1 mL under a -• stream of dry nitrogen and applied to the top of a chromatography column containing 1 g of 5% AX-21 activated carbon in silica gel. The column was eluted with two 2 mL portions of hexane, 2 mL of cyclohexane/methylene chloride (50:50 v/v) and cyclohexane/methanol/toluene (75:20:5 v/v) in the forward direction^ and then with 20 mL of toluene in the reverse direction. The toluene fraction was collected, spiked with recovery standards (1,2,3,4-TCDD-’^Ci2 and 1,2,3,7,8,9- HxCDD-''^Ci2) and taken to a final volume of 20 uL.

. 3

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

CITY_21MC1OO_OO2891243

NYC-WTC_000396364

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000396364Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000395804

Chain-of-Custody data sheet for Pace Analytical project 6526-0279.

Similar indexed content

NYC-WTC_000396381

PACE chain-of-custody accompanying a 30-page Pace Analytical report package.

Similar indexed content

NYC-WTC_000395823

Pace Analytical chain-of-custody form, project data and page count note.

Similar indexed content

NYC-WTC_000396324

Chain-of-custody accompanying a Pace Analytical lab report for the project, listing client and sample identifiers.

Similar indexed content

NYC-WTC_000395785

Chain-of-Custody document for Pace Analytical lab data and pages count.

Similar indexed content

Compare copies and versions →