NYC 9/11 Public Portal Document
FEB-1 M2 14:26 FROM-PACE ANALYTICAL 612-607-6444 T-556 P.D4/06 F-801
’ 1700 Eltn Street - Suite 200
Minneapolis, MN 55414
'yce Analytical_____ ____ Method 8290 Analysis Results
Tel: 612-607-1700
Fax: 512- 607-6444
Client - ATC r—
Client's Sample ID ATC-0129-234M-DX1
Lab Sample ID 103297008 \
Filename F20215A_05
Injected By CVS
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 01/29/2002
I CAL Date 01/24/2002 Received 01/31/2002
CCal Filename(s) F20215A_01 & F20215A_16 Extracted 02/11/2002
Method Blank ID BLANK-1458 Analyzed 02/16/2002 02:23
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.0024 A 2.3,7,8-TCDF-13C 2.00 78
Total TCDF 0.037 0.0020 2,3,7,8-TCDD-13C 2.00 71
1,2,3.7,8-PeCDF-13C 2.00 76
2,3,7,8-TCDD ND 0.0032 A 2,3,4.7,8-P©CDF-13C 2.00 75
Total TCDD 0.120. 0.0020 1,2,3,7,8-PeCDD-13C 2.00 71
1.2.3.4,7,8-HxCDF-13C 2.00 120
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF.13C 2.00 80
2,3,4.7.8-PeCDF 0.024 0.0100 J 2,3,4,6,7,8-HXCDF-13C 2.00 102
Total PeCDF 0,088 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 94
1,2,3,4,7,8-HXCDD-13C 2.00 98
1,2,3.7,8-PeCDD 0.015 0.0100 J 1,2,3,6,7,8-HxCDD-13C 2.00 100
Total PeCDD 0.150 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 88
1,2.3,4,7.8.9-HpCDF-13C 2.00 71
1,2.3.4.7.8-HxCDF 0.017 0.0100 E 1,2,3,4,6,7,8-HpCDD-13C 2.00 80
1,2,3,6,7.8-HxCDF ND 0.0100 OCDD-13C 4.00 52
2,3.4.6.7.8-HxCDF 0.021 0.0100 J
1 ,2,3,7,8,9-HxCDF 0.012 0.0100 J 1,2.3,4-TCDD-13C 2.00 NA
Total HxCDF 0.086 0.0100 1,2,3.7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD 0.015 0.0100 J 2.3,7,8-TCDD-37CI4 0.20 74
1,2,3,6.7.8-HxCDD 0.014 0.0100 J
1,2,3,7,8,9-HxCDD 0.013 0.0100 J
Total HxCDD 0.380 -- 0.0100
1.2,3.4,6,7,8-HpCDF 0.030 0.0100 J Total 2,3,7,8-TCDD
1,2,3,4,7,8.9-HpCDF 0.016 0.0100 I Equivalence: 0.027 ng/m2
Total HpCDF 0.030 0,0100 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.036 0.0100 I
Total HpCDD 0.043 0.0100 J
OCDF 0,030 0.0200 I
OCDD 0.074 0.0200 I-
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7.8-substituled Isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on slgnal-to-nolse measurement S = Saturated signal
J = Concentration detected Ie below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtainea from additional analysis • = Sae Discussion
Report No..... 02-1053614
REPORT OF LABORATORY ANALYSIS
Ttiis report shall not be reproduced, except in full,
wifhout the written consent of Pace Analytical Services, inc.
CITY_21MC100_002890278
NYC-WTC_000395775