NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
'^aceAnalytical_________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax: 612- 607-6444
Client - ATC ASSOCIATES
Client's Sample ID ATC-0430-234M-DX1
Lab Sample ID 103517348
Filename F20513B_09
Injected By MRO
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/30/2002
ICAL Date 05/04/2002 Received 05/07/2002
CCal Filename(s) F20513A_14 & F20513B_14 Extracted 05/10/2002
Method Blank ID BLANK-1616 Analyzed 05/14/2002 02:19
Native Cone EMPC LRL Internal ng's Percent
..J Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3.7,8-TCDF ND 0.0021 A 2.3,7,8-TCDF-13C 2.00 74
J Total TCDF
2,3,7,8-TCDD
0.0025
ND
0.0020 J
0.0023 A
2.3,7,8-TCDD-13C
1,2.3,7.8-PeCDF-13G
2,3.4,7,8-PeCDF-13C
2.00
2.00
2.00
72
69
71
Total TCDD 0.0140 0.0020 1,2,3,7,8-PeCDD-13C 2.00 70
1,2,3,4,7,8-HxCDF-13C 2.00 99
1,2,3.7,8-PeCDF ND 0.0100 1,2,3,6.7,8-HxCDF-13C 2.00 97
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 94
Total PeCDF ND 0.0100 1.2,3,7,8,9-HxCDF-13C 2.00 85
1 1,2.3,4.7.8-HxCDD-13C 2.00 92
1,2,3.7,8-PeCDD ND 0.0100 1.2,3.6,7,8-HxCDD-13C 2.00 96
Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 92
1,2,3,4,7,8,9-HpCDF-13C 2.00 76
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 83
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 54
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7.8-TCDD-37CI4 0.20 74
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1.2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3.7.8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.000043 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1.2,3,4,6,7.8-HpCDD ND 0.0100
Total HpCDD ND 0.0100
OCDF ND 0.0200
OCDD 0.0430 0.0200 J
LRL = Lower Reporting Limit
Cone = Concentration (Totals Include 2,3,7,8-suPstituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected Is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis • = See Discussion
Report No.... 02-1057197
I REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_002889430
NYC-WTC_000395234
OCR can misread numbers and units. Confirm readings against the page image before using them.