NYC 9/11 Public Portal Document
INDUSTRIAL HYGIENE ENVIRONMENTAL TESTING
•EFAKvLTP 101262-0 •NY DOHiNELAC 10903 • NJ DEP PA020
• AIHA ACCREDITATION NO. 100439 •PA DEP 06-353 ‘ CT DPH PH-0238
•NCDENR 599
Analytical Results
ANALYTICAL SERVICES
for
ATC Associates
WorkOrder: R02031094
Client Reference: 19125-0290
Analyte Concentration Limit of Test • Date Analyzed
Detection Method /Analyst
(ug) : (mg/m’) ; (ppm) (ug)
Client ID: M5-ATC-0322-M894 -Lab ID: -05A Date Sampled: 3/22/02 Matrix: Filter Air Vol.(L): NA
Aluminum <1.00 1 N7300 MCE 0^/01/2002 .TH
Cadmium <0.200 0.2 N7300 MCI 04/01/2002 TH
Chromium 0.783 ■ 0.2 N7-3013 MCE 04/01/2002 TH
Cobalt <0.100 N7300 MCE 04/01/2002 TH
Copper <0.200 0.2 N7300 MCE 04/01/2002 TH
Iron ■ <2.00 2 N7300 MCE 04/01/2002 TH
Lead 0.300- . .0.3 N7300 MCE 04/01/2002 TH
Magnesium <1.30 . 1.3 N7300 MCE 04/01/2002 TH -
Manganese <0.300 0.3' N7300 MCE ■ 04/01/2002 TH
Molybdenum <1.00 1 N7300 MCE 04/01/2002 TH'
Nickel <0.200 ■0.2 N7300 MCE 04/01/2002 TH
Zinc <0.500 JLS---—N7300 MCE 04/Q1/20Q2 TH
Client ID: Dustl-ATC-0323-MS94 Lab ID: -06A.^—-Datc Sampled: 3/23/02 Matrix: Filter AirVol.(L): 1440
Total Particulate Matter ■60.0 0.00417 50 ■ N0500 03/27/2002 BSB
Client ID: Hgl-ATC-0322-M894 Lab ID: -07A Date Sampled: 3/22/02 Matrix: HTBE AirVol.(L): 120
Mercury 0.0280 0.000233 0.01 N6009M 03/27/2002 JDC
T?
Client ID: Hg2-ATC-0322-M894 Lab ID: -08A Date Sampled; 3/22/02 Matrix: HTBE AirVol.(L): 120
Mercury 0.0280 0.000233 0.01 N6009M 03/27/2002 .JDC
9
Client ID: Hg3-ATC-0322-M894 Lab ID: -09A Date Sampled: 3/22/02 Matrix: HTBE AirVol.(L): 120
Mercury 0.0280 0.000233 0.01 N6009M 03/27/2002 JDC
0
Client ID: Hg4-ATC-0322-M894 Lab ID: -lOA Date Sampled: 3/22/02 Matrix: HTBE AirVol.(L): 120
Mercury 0.0280 0.000233 . 0.01 N6009M 03/27/2002 JDC
1)
Client ID: Hg5-ATC-0322-M894 Lab ID; -1 1A Date Sampled: 3/22/02 Matrix: HTBE Air Vol.(L): NA
Mercury 0,0280 0.01 N6009M 03/27/2002 JDC
Page 3 of 8
CITY_21MC1OO_OO2918424
NYC-WTC_000394661
OCR can misread numbers and units. Confirm readings against the page image before using them.