DEC.14.2001 12:38PM JLC ENVIRONMENTAL NO.449 LC ENVIRONMENTAL CONSULT, ..iTS, INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 Phone: (212) 420-8119 Fax: (212) 420-6092 Project No.:' 01-2240 WSA MBnagemant ELAP Lab Code: 11029 Analyte'. FIBERS : 100 Ring Road West NIOSH and AIHA Lab Code; 100273 Date Received: 12/13/01 Garden City, NY 11530 NVLAP Lab Coda; 1019S3 Date Analyzed: 12/13/01 Batch#; 01124978; SUMMARY OF ANALYTICAL RESULTS - PCM I Site: 1 I 80 John Street, New York, NY

=a sample# COLLECTED DESCRIPTION I LOCATION TIME(mln) VOLUME(L) FIB/FIELO RESULTS(Vcc) LAB#

001 Ambient/ 4th Floor/ Apartment 46/ Living Room/ 90 1352.7 2/100 <0.001<LOD ' 13-Deeember East Wall/ Near Door A 9964

002 Ambient/4th Floor/Apartment 46/West 90 1352.7 2/100 <0 001 <LOD 13.December Bedroom on West/ Near Closet A 9965

003 Ambient/ 12th Floor/Apartment 12F/ North East 90 1352.7 3/100 O.OOKLOD 13-December Bedroom on South/ Near Door A 9866 I-

004 Ambient/ 12th Floor/ Apartment 12F/ Living 90 1352.7 2/100 <0.001 <LOD 13-December Room/ Kitchen/ Counter South A 9867

005 Ambient/ 4th Floor/ Corridor/ South Side With 90 1352.7 4/100 , O.OOKLOD 13-DBcernber South Wall A 9868

006 Ambient/ 4th Floor/ Corridor/ North Side With 90 1352.7 7/100 0.002 13-Deoamber North Wall A 9869

4

Sample Ar.alyais by: <1.00 = Less than limit of detectian which la 5.5 Fibers/100 Fields VOID1 = H.C.P. (High Concentration of Partidas) Positive Phase Contrast Microscopy (PCM) VOID2 = Overloaded Method of Sample Preparation and Analysis: All samples analyzed in accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2. August 1994 Instrumentation: Olympus PCM Model BH-2 with Wblton-Beckstt Graticule (tOOuin field diameter). uuiam Macnniwaia Laboratory Director Report Date: December 13. 2001 ILL* b responsible for only tha liber counts within the limitations of the method described asNIOSH 7400. Among other limitaQons, this meth give', only an index of akbomo libera and pravides only ar ssBmate of asbestos concentration. Any and all ciaims arising out of JLCs analyd these samples are limited In recovery to the cost of analyzing samples. JLC accepts no other liability and the cNent agrees to seek no costs b the above. Psge 1 of 2

CITY_21MC100_002885766

NYC-WTC_000390320

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000390320Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →