’ C ENVIRONMENTAL CONSULT ^S, INC. ■ 'arkAvenue South, Suite 1001, New York, N6.^ brk 10003 Phone: (212) 420-8119 Fax: (212) 420-6092 Project No.; 01-2171 WSA Management ELAP Lab Code: 11029 Analyte: FIBERS 100 Ring Road West NIOSH and AIHA Lab Code: 100273 Date Received: 10/29/01 Garden City, NY 11530 NVLAR, Lab Code: 101953 Date Analyzed: 10/29/01 Batch#: 0110A830 SUMMARY OF ANALYTICAL RESULTS Site; 80 John Street, New York, NY

SAMPLE # COLLECTED DESCRIPTION I LOCATION TIME(min) VOLUME(L) FIB/FIELD RESULTS(f/cc) LAB#

001 Ambient/ Apt. 17C South/ Near Entrance to 120 1803 5/100 O.OOKLOD 26-October Bedroom Near Closet A 8408

002 Ambient/ Apt. 17C North East Room/ In the 120 1803 6/100 0.002 26-October Middle (Column) A 8409

003 Ambient/ Apt. 11th Floor Hallway/ Elevator 120 1803 5/100 O.OOKLOD 26-October Hallway on South Side (East Wall) A 8410

004 Ambient/ Apt. 11th Floor Hallway/ Elevator 120 1803 4/100 O.OOKLOD 26-October Hallway on North Side (East Wall) A 8411

005 Ambient/ Apt. 11th Floor Apt, 11B/ West Side 120 1803 7/100 0.002 26-Ootober Bedroom/ N-Wear Closet A 8412

006 Ambient/ Apt. 11th Floor Apt. 11B/ East Side 120 1803 6/100 0,502 26-October Bedroom/ North West Near Door A 8413

Sample Analysis by: <LOD = Less than limit of detection which is 5.5 Fibers/100 Fields Positive Phase Contrast Microscopy (PCM) VOID1 = H.C.P. ( High Concentration of Particles) VO1D2 = Overloaded Method of Sample Preparation and Analysis: All samples analyzed in accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2, August 1994 Instrumentation: Olympus PCM Model BH-2 with Walton-Beckett Graticule (100um field diameter). Laboratory Director Report Date: October 30, 2001 JLC is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400. Among other limitations, this meth gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of JLC's analyst these samples are limited in recovery to the cost of analyzing samples. JLC accepts no other liability and the client agrees to seek no costs b the above. Page 1 of 2

CITY_21MC100_003796874

NYC-WTC_000390300

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000390300Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000390351

Analytical results for airborne fibers at 80 [name], NY, including lab batch 0111A914.

Similar indexed content

NYC-WTC_000390360

Air and fiber results for 80 [name], NY, including lab details and sample times.

Similar indexed content

Compare copies and versions →