z z o o i 1^ co
■D o c o o Contribuition to risk of various asbestos dust levels CT o o' 00 co "0 CD Risk = Conc(f/cc) * TWF * Slope factor o KJ CJ> TWF is weighting factor for partial exposure (less than 70 years, 24 hrs a day) 03
Slope factor of 0.23 f/cc used over a 70 year exposure O o o c Low Fiber loading 1000 f/cm2 3 CD 3 Scenario Activity loading K factor Air Ie,'el Years days/year hours/day TWF Contribution to Risk f/cc 1 Year exposure 1 Daily activi 1000 1.0E-07 1.00E-04 1 350 24 0.013699 3.15E-07 2 Cleaning 1000 1.0E-06 1.00E-03 1 50 2 0.000163 3.75E-08 3.53E-07
30 Years exposure 1 Daily activi 1000 1.0E-07 1.00E-04 30 350 24 0.410959 9.45E-06 2 Cleaning 1000 1.0E-06 1.00E-03 30 50 2 0.004892 1.13E-06 1.06E-05
70 Years exposure 1 Daily activi 1000 1.0E-07 1.00E-04 70 350 24 0.958904 2.21 E-05 2 Cleaning 1000 1.0E-06 1.00E-03 70 50 2 0.011416 2.63E-06 2.47E-05
Moderate Fiber loading, 10,000f/cm2 Scenario Activity loading K factor Air level Years days/year hours/day TWF Contribution to Risk f/cc 1 Year exposure 1 Daily activi 10000 1.0E-07 1.00E-03 1 350 24 0.013699 3.15E-06 2 Cleaning 10000 1.0E-06 1.00E-02 1 50 2 0.000163 3.75E-07 3.53E-06
Q 30 Years exposure H 1 Daily activi 10000 1.0E-07 1.00E-03 30 350 24 0.410959 9.45E-05 2 Cleaning 10000 1.0E-06 1.00E-02 30 50 2 0.004892 1.13E-05 1.06E-04 S o 70 Years exposure o o 1 Daily activi 10000 1.0E-07 1.00E-03 70 350 24 0.958904 2.21 E-04 I o o
CO co co
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000389919
Risk contributions for asbestos exposure scenarios using K factors and TWF values.
2 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000389921
Draft COC discussing actions, screening values, and risk estimates for asbestos exposure.
3 shared non-person entities · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163599
Draft screening levels for asbestos, fiberglass and silica in indoor air and settled dust.
3 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164830
DEP internal memo circulating draft EPA screening level standards for asbestos, fiberglass, and silica in indoor air and settled dust for agency comment.
3 shared non-person entities · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164455
Correspondence discussing draft EPA screening levels for asbestos and silica in indoor air and settled dust during post-WTC response.
3 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242039
Asbestos dust risk calculations and exposure contributions.
3 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337603
Risk calculations for asbestos dust exposure scenarios.
2 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176160
Draft assessment summarizing eight months of monitoring data regarding air, dust, and water contaminants at the WTC site and surrounding areas.
3 shared non-person entities · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320378
Draft lab report evaluating insulation wools and exposure reduction actions for fibrous glass.
3 shared non-person entities · 1 shared topics · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337617
Sampling plan table for 14 buildings and 42 units total.
3 shared non-person entities · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317656
Draft COPCs selection and discussion of indoor environmental risks post-9/11.
3 shared non-person entities · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250295
Draft COC document with action levels and contamination conditions for asbestos.
2 shared non-person entities · 1 shared topics · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000164455
Correspondence discussing draft EPA screening levels for asbestos and silica in indoor air and settled dust during post-WTC response.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000159817
Circulation of draft environmental screening benchmarks for asbestos, fiberglass, and silica in indoor air and settled dust for expert review.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160806
Forwarded EPA draft guidance on screening levels for asbestos, fiberglass, and silica in indoor air and settled dust for departmental review.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163599
Draft screening levels for asbestos, fiberglass and silica in indoor air and settled dust.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342460
Risk assessment calculations for asbestos dust exposure and related factors at WTC site.
Similarity score 0.981 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164830
DEP internal memo circulating draft EPA screening level standards for asbestos, fiberglass, and silica in indoor air and settled dust for agency comment.
Similarity score 0.981 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000163599
Draft screening levels for asbestos, fiberglass and silica in indoor air and settled dust.
Similar indexed content
NYC-WTC_000164830
DEP internal memo circulating draft EPA screening level standards for asbestos, fiberglass, and silica in indoor air and settled dust for agency comment.
Similar indexed content
NYC-WTC_000164455
Correspondence discussing draft EPA screening levels for asbestos and silica in indoor air and settled dust during post-WTC response.
Similar indexed content
NYC-WTC_000389919
Risk contributions for asbestos exposure scenarios using K factors and TWF values.
Similar indexed content
NYC-WTC_000242039
Asbestos dust risk calculations and exposure contributions.
Similar indexed content