DRAFT COC Airborne Screening Levels May 15, 2002 Insulation wools: Glass wool, rock wool and slag wool

Level Recommended actions Comments

Air level: Evaluate the need to remove sensitive ACGIH TLV of 1 f/cc based on limiting >0.1 f/cc * individuals from the environment irritant effects of fibrous glass. Uncertainty factor of 10 for application to a Evaluate conditions in the area non-worker population. including representativeness of air samples, fibrous glass dust levels and loading. Settled dust threshold based on Millette’s Settled Dust level; work using K factors to estimate airborne Take actions to reduce exposures. levels for different activities. Although not > 100,000 f/cm" - clean area rigorous enough to rely upon for a firm - resample health call, it is only used here to define - ongoing cleaning what might constitute elevated fiber counts which would need to be addressed as a near term concern. This approach may overestimate potential exposures, but as such would be protective if clean-up action is taken. Although the K factor is based on activity data for asbestos, it is believed to be protective for the larger insulation wool fibers which would be less airborne.

Air level: Evaluate conditions in the area For those areas where air levels would not 0.01 -0.1 f/cc* including representativeness of air warrant removal of sensitive individuals, samples, fibrous glass dust levels and but are above the 0.01 f/cc, continued loading. cleaning and evaluation is prudent. Or

Settled Dust level; If air samples were not taken, then Settled dust threshold is set at that appropriate air sampling should be found in background, or unaffected conducted to determine if fiber levels areas. In this way, no increase in risk Background are elevated. due to the fibers would be expected. To 100,000 f/cm^ Take actions to reduce exposures. - clean area - resample - ongoing cleaning

Air level: No action required ACGIH TLV of 1 f/cc based on limiting <0.01 f/cc * irritant effects of fibrous glass. , Uncertainty factor of 100 for application to a non-worker population. This factor also And takes into account weighting the exposure over daily and long-term exposures. Settled Dust level: background Settled dust threshold is set at that ; found in background, or unaffected areas. In this way, no increase in risk due to the fibers would be expected..

* Fibers with length > 5,um with an aspect ratio > 3:1, as defined in the ACGIH TLV. Air concentrations measured by PCM, NIOSH 7400, confirmed by SEM.

CITY_21MC100_006729560

NYC-WTC_000320378

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320378Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →