Insulation wools draft evaluation, 2002

Machine-extracted title · confidence 28%

Draft lab report evaluating insulation wools and exposure reduction actions for fibrous glass.

NYC-WTC_000320378–000320380
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

DRAFT COC Airborne Screening Levels May 15, 2002 Refractory Ceramic Fibers (RCF) Level Recommended actions Comments Air level: Consider removing sensitive individuals ACGIH TLV of 0.2 f/cc based on plural and >0.01 f/cc * from the environment lung function abnormalities and a potential for carcinogenic effects after long term exposures. Evaluate conditions in the area Although quantitative risk estimates are not including representativeness of air available, RCF is expected to be intermediate Settled Dust level: samples, fibrous glass dust levels and in its toxic effects between other forms of > 10,000 f/cm^ loading. fibrous glass and asbestos. Therefore, in the Take actions to reduce exposures. face of uncertainty, a conservative approach is - clean area to set screening values for RCF similar to - resample those for asbestos. - ongoing cleaning Settled dust threshold based on Millette’s work using K factors to estimate airborne levels for different activities. Although not rigorous enough to rely upon for a firm health call, it is only used here to define what might constitute elevated fiber counts which would need to be addressed as a near term concern. This approach may overestimate potential exposures, but as such would be protective if clean-up action is taken.

Air level: Evaluate conditions in the area See above Background including representativeness of air To samples, fibrous glass dust levels and 0.01 f/cc * loading.

Or If air samples were not taken, then appropriate air sampling should be Settled Dust level: conducted to determine if fiber levels Settled dust threshold is set at that found in are elevated. background, or unaffected areas. In this way, background no increase in risk due to the fibers would be To expected. 10,000 f/cm^ Take actions to reduce exposures. - clean area - resample - ongoing cleaning

Air level: No action required i background Settled dust threshold is set at that found in Andi background, or unaffected areas. In this way, no increase in risk due to the fibers would be Settled Dust level: expected. ' <. background

* Fibers with length > 5wm with an aspect ratio > 3:1, as defined in the ACGIH TLV.

CITY_21MC100_006729561

NYC-WTC_000320379

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320379Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →