AMBIENT LABS, INC. 159 WEST 25TH STREET NEW YORK, NY 10001 BULK SAMPLE LABORATORY DATA REPORT PROJECT: 0211512 COLLECTED: 11/5/2001 BATCH ID: 3422 SIGNED FOR AMBIENT LABS INC. BY: CLIENT: AMEX Towers DATEREC'D: 11/6/2001 LOCATION : 3 World Financial Center TIMEREC'D: 9:42 AM TECHNICIAN: CANCEL ANALYZED: 11/6/2001

PERCENTOF LABORATORY ID FIELD ID SAMPLE SAMPLE ASBESTOS TOTAL SAMPLE NUMBER NUMBER COLOR DESCRIPTION PRESENT ASBESTOS CONSTIUTENTS

B2K91714 4-04-A Gray WINDOWSILL. YES 0.50 % (P) CHRYSOTILE: .50 % CELLULOSE; 30.00 % MINERAL WOOL: 30.00 % NON-FIBROUS : 39.50 % B2K91715 4-05A Gray TOP SHELF. NAD 0.00 % (P) CELLULOSE: 30.00 % MINERAL WOOL; 30.00 % NON-FIBROUS : 40.00 % B2K91716 4-06A Gray TREADMILL NEAR WINDOW. YES 5.00 % (P) CHRYSOTILE; 5.00 % CELLULOSE: 10.00 % MINERAL WOOL: 40.00 % NON-FIBROUS : 45.00 % B2K91717 4-07A Gray FLOOR OF EXCERCISE ROOM. YES 5.00 % (P) CHRYSOTILE: 5.00 % CELLULOSE: 10.00 % MINERAL WOOL: 40.00 % NON-FIBROUS: 45.00 % B2K91718 4-08A Gray WINDOW SILL. NAD 0.00 % (P) CELLULOSE: 40.00 % MINERAL WOOL: 20.00 % NON-FIBROUS: 40.00 % B2K91719 4-09A Gray TOP OF FILING CABINET. YES 0.24 % (P) CHRYSOTILE: TRACE o CELLULOSE: 30.00 % H MINERAL WOOL; 40.00 % NON-FIBROUS : 30.00 % re S n NAD = No Asbestos Detected. Trace < 0.25 %. o (P) Analysis by Polarized Light Microscopy (PLM) NYS ELAP method 198.1 or EPA/600/R-93/116. (T) Analysis by Transmission Electron Microscopy (TEM) NYS ELAP method 198.4. Polarized Light Microscopy is not consistently reliable in detection of asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently I the only method that can be used to detemnine if this material can be considered or treated as non-asbestos containing. No reproduction of all or any portion of this report shall occur without written o approval of Ambient Labs, Inc. All results disclosed in this report relate only to the items tested. o re NVLAP ID #101618. NYS ELAP ID# 10865. STATE OF CA ELAP ID # 2139. co Ui

o co 0-

NYC-WTC_000389250

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000389250Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →