NYC 9/11 Public Portal Document
AMBIENT LABS, INC.
159 WEST 25TH STREET
NEW YORK, NY 10001
BULK SAMPLE LABORATORY DATA REPORT
PROJECT: 0211512 COLLECTED: 10/30/2001 BATCH ID : 3409 SIGNED FOR AMBIENT LABS INC. BY:
CLIENT: Lehman Brothers DATEREC'D: 10/31/2001
LOCATION: 1WFC&3WFC TIMEREC’D: 3:39 PM
TECHNICIAN: PETE SCHORK ANALYZED: 10/31/2001
PERCENTOF
LABORATORY ID FIELD ID SAMPLE SAMPLE ASBESTOS total SAMPLE
NUMBER NUMBER COLOR DESCRIPTION PRESENT ASBESTOS- CONSTIUTENTS
B2K91548 3-01 Gray ON TH E 3RD FLOOR CAFETERIA. YES 0.24 % (P) CHRYSOTILE : TRACE
CELLULOSE: 30.00 %
MINERAL WOOL : 30.00 %
NON-FIBROUS: 40.00 %
B2K91549 4-01 Gray ON HE 4TH FLOOR SEE DRAWING. YES 2.00 % (P) CHRYSOTILE: 2.00 %
CELLULOSE : 30.00 %
MINERAL WOOL: 30.00 %
NON-FIBROUS : 38.00 %
B2K91550 4-02 Gray ON THE 4TH FLOOR SEE DRAWING. YES 2.00 % (P) CHRYSOTILE: 2.00 %
CELLULOSE : 30.00 %
MINERAL WOOL: 30.00 %
NON-FIBROUS : 38.00 %
B2K91551 4-03 Gray ON THE 4TH FLOOR SEE DRAWING. YES 0.80 % (P) CHRYSOTILE: .60 %
CELLULOSE: 30.00 %
MINERAL WOOL ; 40.00%
NON-FIBROUS : 29.20 %
B2K91552 5-01 Gray ON THE STH FLOOR SEE DRAWING. YES 2.00 % (P) CHRYSOTILE : 2.00 %
CELLULOSE: 30.00 %
MINERAL WOOL: 30,00 %
NON-FIBROUS : 38.00 %
o
H
[\0
S NAD = No Asbestos Detected. Trace < 0.25 %.
O (P) Analysis by Polarized Light Microscopy (PLM) NYS ELAP method 198.1 or EPA/600/R-93/116. (T) Analysis by Transmission Electron Microscopy (TEM) NYS ELAP method 198.4. Polarized
o Light Microscopy is not consistently reliable in detection of asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy Is currently
o the only method that can be used to determine if this material can be considered or treated as non-asbestos containing. No reproduction of all or any portion of this report shall occur without written
I approval of Ambient Labs, Inc. All results disclosed in this report relate only to the items tested.
o NVLAP ID# 101618. NYS ELAP ID# 10865. STATE OF CA ELAP ID # 2139.