NYC 9/11 Public Portal Document
MSDS Number; 2008FR Page 6 of 7
exposures to 50,000 ppm (v/v) of vapors produced organ
weight increases and a decrease in body weight gain, but no
increased mortality or adverse hematological effects. In
chronic inhalation studies, "FRECM" 22, at a concentration o
50,000 ppm (v/v), produced a small, but statistically
significant increase of late-occurring tumors involving
salivary glands in male rats, but not female rats or male or
female mice. In the same studies, no increased incidence of
tumors was seen i.n either species at concentrations of
10,000 ppm or 1,000 ppm (v/v).
Lcng-tsrm administration in corn oil produced no effects on
body weight or mortality.
"FREON" 22 was mutagenic in some strains of bacteria in
bacterial cell cultures, but not mammalian cell cultures or
animals. It did not cause heritable genetic damage in
mammals.
A slight, but significant increase in developmental toxicity
was observed at high concentrations (50,000 ppm) of
"FREON" a concentration which also produced toxic
effects in the adult animal. Based on these findings, and
ocher negative developmental studies, "FREON" 22 is not
considered a unique hazard to the conceptus. Studies of
the effects of "FREON" 22 on male reproductive performance
have been negative. Specific studies to evaluate the effect
on female reproductive performance have not been conducted,
however, limited information obtained from studies on
developmental toxicity do not indicate adverse effects on
female reproductive performance at concentrations up to
50,000 ppm.
=:
ECOLOGICAL INFORMATION
Ecotoxicological Information
Aquatic Toxicity:
"FREON" 22
48 hour EC50 - Daphnia magna: 433 mg/L
DISPOSAL CONSIDERATIONS
Waste Disposal
Comply with Federal, State, and local regulations. Reclaim
by distillation or remove to a permitted waste disposal
facility.
TRANSPORTATION INFORMATION
Shipping information
DOT,'IMO
Proper Shipping Name CHLORODI FLUOROMETH ail E
Hazard Class 2.2
http://wwwdupont.com/msds/40_j 7_2008fr. html 2/13/2002
CITy_21MClb0_002884503
NYC-WTC_000388866
OCR can misread numbers and units. Confirm readings against the page image before using them.