NYC 9/11 Public Portal Document
228 East 45th Street
10th Floor
WKP New York NY 10017
Tel (212) 922 0689
LABORATORIES INC Fax (212) 922 0630
AIR SAMPLE ANALYSIS REPORT
PHASE CONTRAST MICROSCOPY
CLIENT WARREN & PANZER ENGINEERS P C TURNAROUND TIME 24 HOURS
WKP FILE # 50101 SAMPLE DATE 9/17/98
WKP LOG ID # N980989 RECEIVED DATE 9/18/98
ANALYSIS DATE 9/18/98
REPORT DATE 10/12/98
CLIENT JOB DDC
CLIENT JOB # 821 80 01
LOCATION HIGHLAWN BRANCH LIBRARY 1664 N13TH ST
ANALYSIS AIRBORNE FIBER COUNTING PHASE CONTRAST MICROSCOPY NIOSH 7400
NIOSH PAT Lab NO 07186 NY STATE ELAP Lab NO 11092/11251
COLLECTION DEVICE 25 mm MCE Filter Cassette Collection Area = 385 sq mm
Field Area = 0 00785 sq mm
SAMPLE WERE COLLECTED BY G BAER
SUMMARY OF ANALYSIS
CLIENT SAMPLE VOLUME FIBERS/ FIBERS/
SAMPLE# LOCATION (LITERS) sq mm cc
050 CLEAN RM DECON 1225 0 000 <004
051 OUTSIDE DECON 1225 0 000 <004
052 STAIRCASE TO BOILER RM 1225 2 500 <004
053 BY NEG AIR EXHAUST 1225 0 000 <004
054 1ST FLOOR LIBRARY 1225 4 500 <004
055 CLEAN RM DECON 550 1 300 <009
056 OUTSIDE DECON 550 1 300 <009
057 STAIRCASE TO BOILER RM 550 0 000 <009
058 BY NEG AIR EXHAUST 550 5 100 <009
059 1ST FLOOR LIBRARY 550 4 500 <009
060 FIELD BLANK
061 FIELD BLANK
NOTES 10 fibers/100 fields was used to calculate the lower limit of quantification (LOQ) Results below the
LOO have no statistical validity
Samples were not collected by WKP Laboratones Inc
The Federal EPA Clearance Cntena following an asbestos abatement project is 0 010 fibers/cc
PCM air samples will be disposed of after 3 months unless otherwise directed by client in wnting
LABORATORY ANALYST LABORATORY DIRECTOR