Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
WTC Occupational Exposure Limit List
Adjustment Adjustment Shift Adj.
Agent Category Factor TLV PEL OEL OEL Comment
Metals
Welding Fume I! 0.67 5 5 5 3.35 (mg/m3) PEL is for respirable dust
Aluminum I-C 1 5 5 5 5 (mg/m3) TLV for metal fume PEL for respirable fraction
Antimony III 0.48 0.5 0.5 0.5 0.24 (mg/m3)
Arsenic III 0.48 0.01 0.01 0.01 0.0048 (mg/m3) PEL STEL = 1.0
Beryllium III 0.48 0.002 0.002 0.002 0.0010 (mg/m3) PEL C= 0.005; TLV STEL = 0.01; NIC = 0.0002
Inhalable
Cadmium III 0.48 0.002 0.005 0.002 0.0010 (mg/m3) TLV for respirable; See Table Z-2 for exclusions in 29
CFR 1910.1027
Calcium 1-B 1 2 5 2 2 (mg/m3)
Chromium III 0.48 •0.5 1 0.5 0.24 (mg/m3) VI TLV = 0.05; VI PEL = C 0.1
Cobalt III 0.48 0,02 0.1 0.02 0.010 (mg/m3)
Copper II 0.67 0.2 0.1 0.2 0.134 (mg/m3)
Iron III 0.48 5 10 5 2.4 (mg/m3) Iron Oxide; PEL as fume
Lead III 0.48 0.05 0.05 0.05 0.024 (mg/m3)
Magnesium II 0.67 10 15 10 6.7 (mg/m3) As fume
Manganese IV 0.67 0.2 5 0.2 0.134 (mg/m3) PEL Is Ceiling
Nickel III 0.48 1.5 1 1.5 0.72 (mg/m3) TLV as inhaiable
Selenium IV 0.67 0.2 0.2 0.2 0.134 (mg/m3)
Thallium III 0.48 0.1 0.1 0.1 0.048 (mg/m3) Skin (both)
Tin III 0.48 2 2 2 0.96 (mg/m3)
Titanium 1-C 1-C 10 15 10 10 (mg/m3)
Vanadium 1-B 1-B 0.05 0.1 0.05 0.05 (mg/m3) TLV for fume; PEL is C for fume
Zinc II 0.67 5 5 5 3.4 (mg/m3) Both as fume
Aldehydes
Acetaldehyde 1-B 1 25 200 25 25 (ppm) TLV is C
Acrolein 1-B 1 0.1 0.1 0.1 0.1 (ppm) TLV Is C
Benzaldehyde 2 2 2 (ppm) TLV = WEEL: WEEL STEL = 4
Formaldehyde 1-A 1 0.3 0.75 0.3 0.3 (ppm) TLV = C: PEL STEL = 2
n-Butyraldehyde 25 25 25 (ppm) TLV = WEEL
Q Propionaldehyde 20 20 20 (ppm) TLV = NIC for 2001
H Valeraldehyde 50 50 50 (ppm)
K
I
I
o
Aromatics
o
I
o Key:
o
to
co
1. OEL = the lower of the TLV and PEL
co 2. NIC = Notice of Intended TLV Change value
to
o 3. WEEL ^J^kplace Environmental Exposure Limit (AIHA) Page
Ui
NYC-WTC_000387614
OCR can misread numbers and units. Confirm readings against the page image before using them.