KAM CONSULTANTS
35-4036lhStreet
Long Island City
NewYorM1106
Tel:(718}729-1997
Fax:(718)729-1876
ANALYSIS REPORT
ASBESTOS IN AIR
Transmission Electron Microscopy
CLIENT: Department of Design and Construction - 30-30 Thomson Avenue, Long Island City, NY 11101
PROJECT ADDRESS: Stuyvesant H.S., 345 Chambers St, NY, NY 10282 Pier #25
Lab ID# CUent Sample Location Volume Grid FUter Analytical Asbestos Asbestos Structures Detected Structure Density Structure
Sample fbters) Openings Area Sensitivity Type(s) (microns) (sttuc/mm^) Total Concentration
ID# Examined (mmj (stnict/cc air) (struc/cc)
0.5-5.0 >5.0 Total Total
T020327A-01 1 North E.xit of Stuyvesant H.S. 1800 6 385 0.0043 NT) 0 0 0 <20.00 <0.0043
TO20327A-02 2 Stuyvesant H.S. North West Site 1800 6 385 0.0043 ND 0 0 0 <20.00 <0.0043
Area Analyzed: 0.0600 mnr Date Received: 03/27/02
O Grid Opening Area: 0,010 mm' Date .Analyzed: 03/27/02
H Date Collected: 03/26/02(7:00-17:00) yv of Report:
Date ot
Date Report: 03/28/02
03/28/02 / 7
_____________________ Lah Manage/ )
.Analyst:
Alex Barengolts Y David Chen\^
s Analysis performed according to AHERA Method (EPA 40 CFR Part 763 - Appendix A).Samples will be stored for ninety (90) days and then returned to the client upon request. _ __
O
Sample volume is below recommended limit of the method
O AIHA #: 100269 NIST-NVLAP#; 102047 NYS-DOH EL/VP#: 11273
O
I
o
o
cn
co
co
cn Page 1 of 1