NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Investigation narrative, NYS Dent. Office, 1987

Machine-extracted title · confidence 42%

Investigation narrative of a complaint at a NYC building, with disposal and inspection details.

NYC-WTC_000386346
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

OF SAFETY A\D HEALTH SAFETY AND HEALTH

INVESTIGATION NARRATIVE 1 REPORTING I D. . 255850_______ /86-CP-H-NY-M-LL3 2 PAGE 1_ OF__ 1 3. INVESTIGATION ( Type and Number) 4. ESTABLISHMENT NAME AND SITE ADDRESS

E COMPLAINT 70182852 NYS Dent. 3f Health Office of Health System Management □ ACCIDENT 35 W. 54th St. NYC 1 )001 □ OTHER (Specify)i 5. DATE(S) OF IN''ESTIGATION 6. INSPECTION NUMBER

Mar. 17. 1)8?______ 102149952 7. NARRATIVE REPORT

The above premises were inspected on Mirch 17, I987, in response to a complaint concerning respiratory problems, odors, and mouse infestation. An opening conference was held with Ms Marianne Fogarty, Assistan: Director for Long Term Care Services, representing the employer and Mr. Douglas Nimetz, Health Program Administrator, re­ presenting the employees (PEF).

The building is an 11 story masonry structure, converted from a department store/ storage facility. It has general dilution mechanical ventilation, and openable windows. OHMS occupies, the third floor; the complain*: concerns the coordination unit on the north (55th St.) side of the building. This is a large open office area, 50 ft. by 50 ft. by 8 ft. high, with no windows, and seven air 1 supply registers. Personnel were complaining that air was supplied only intermittently, -.hat particulates and odors were a problem, and that their health was adversely affectei. by the poor air quality. At the time of inspection (mid-afternoon) it was confirmed that no air was being supplied to the room, since the relevant NV/ machine room unit was not functioning. The following measurements were made (with a GFG Polytector and Draegej pump/direct reading detector tubes) to ascertain air quality and possible contamimnt levels:

MAIN OFFIC} SMALL CORNER OFFICE

Temperature 80OF 770F Humidity- 51^ 53% Air Flow 0 0 Oxygen 20.5^ 20 Carbon Dioxide 800 ppm 1200 ppm Carbon Monoxide 3 ppm Not Detected

The mail room/photocopier was also tested for ozone, with negative results. It was supplied with fresh air through an open window. In the main office, particulates were observed on work surfaces and files under the air registers, but since air flow was zero at time of inspection, air samples were not teiken. No violations of the OSHA air contaminant standard 29 CFR 1910.IC00 were found, and items #1 and 2 of the complaint were not sustained.

The area was inspected for evidence of rodent infestation, which was found in two places. OSHA 1910.141 (a)(5) states, "Vermin Control Every enclosed workplace shall be so constructed, equipped, and maintained, so far as reasonably practicable, as to prevent the entrance or harborage of rodents, insects and other vermin. A continuous and effective extermination program shall be instituted where their presense is detected.'*'' Mr. Nemetz showed documentatio 1 that an extermination program monitored through the NYS Department of Health was red icing the infestation level markedly, sc Item #5 of the complaint was not sustained. 8. ORDERS ISSUED 9. SIGNATURE OF INSPECTOR/HYGIENTIST 10. DATE

□ yes 6 no Sylvia C. Pryce L 4/7/87

DOSH-914 (2-86)

NYC-WTC_000386346

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000386346Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000137983

Archival folder label for Health Department forms related to World Trade Center activities from 1999 to 2001.

Similar indexed content

Compare copies and versions →