NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Bulk sample analysis report, 14-22 [name] St, Manhattan

Machine-extracted title · confidence 42%

Bulk sample analysis results for NYC-DCAS at 14-22 [name], Manhattan.

NYC-WTC_000386163
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUIWS 35-40 a€th Street Long Island City NevYork,11106 Tel:{718)729-W Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS; 14-22 Reade Street, Manhattan PROJECT#: Client Sample ID# 41C 42A 42B 42C 43A Lab Sample ID? 010905B-255 010905B-256 010905B-: 010905B-258 010905B-259 Sample Location Roof'D" Roof'D" Roof'D" Roof'D" Roof "D"

Homogeneitx Yes Yes Yes Yes Yes Sample Description Roof Membrane Roof Membrane Roof Membrane Roof Membrane Base Flashing 3rd Layer 1st Layer 2nd La_\er 3rd Layer 1st Layer

Color BIk Blk Blue Blk Blk Texture Non Fibrous Non Fibrous Non Fibrous Non Fibious Mixed Sample Treatment Acid Digestion Acid Digestion Acid Digestion Acid Digestion Acid Digestion & Ashing & Ashing & Ashing & Ashing & Ashing Asbestos Present (Type & Percent) ND ND ND ND 16 02%CHR Total Percent Asbestos: 0% 0% 0% 0% 16.02% Other Fibr Mat (Type & Percent) 0% 0% 0% 0% 0% Non Fibr Mat (Percent)' 100% 100% 100% 100% 83 98% Date Received 9/5/01 Date of Analysis 9/6/01 Date of Report- 9/7/01

Analyst: > Q[ 1 Lab Man M. Ulanecki David Chen " * Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) ♦ Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested ♦ The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP #11273 NIST-NYLAP # 102047 AIHA #: 100269

20

NYC-WTC_000386163

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000386163Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →