NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 18 pages

Chain of custody, NYC-DCAS lab samples

Machine-extracted title · confidence 25%

Chain-of-custody forms for DCAS NYC lab samples and recipient details.

NYC-WTC_000386129–000386146
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

5:33PM8 abbociateb llc ID-84-5 948 B4SSNo.t999 P. ’PST/IS

Adelaide Associates, LLC B

(including no paints or glues).

Lead Air Sampling

The ambient and personnel air sampling levels set by OSHA need to be below the permissible exposure limit (PEL) of 50 micrograms per cubic meter (ug/m’). If workers are exposed to levels above this limit, certain medical surveillance monitoring, as well as appropriate engineering controls and personnel protective equipment (PRE) are required. Several samples were above the PEL during this project.

Ambient air sampling was conducted in accordance with OSHA recommended guidelines. A personal low volume air pump was placed in the breathing zone (4-8 feet) and the air was collected onto a 0,8 micron . 37 millimeter cassette. The cassettes were sent to a laboratory for analysis.

AsbestoB A(rS Ilina

Air sample collection and analysis was conducted throughout the abatement project. The purpose was to document the effectiveness of the contractor's efforts at confining asbestos to the work zone. The program Included air sampling and analysis by PCM [National Institute for Occupational Safety and Health (NIOSH) Method 7400].

NIOSH Method 7400 involves the analysis of ail airborne particulate contaminants captured on a filter medium utilizing vacuum pumps. Sampling cassettes were pre and post calibrated for flow rate in the field utilizing hand held rotometers, which in turn are calibrated against a primary standard in the laboratory. Air samples are then transmitted to the laboratory with a Chain of Custody where, after preparation, they are examined under PCM. Criteria speciflad for fiber counting is fiber length, length to width ratio, and morphological characteristics.

IntiMirtal / OSHA CampUMet Swieas fAabaatoa A LaaP ConsuMng Gammuntt/ HtOf Aaaaaamant/Huanloua MataM Abalamant

Received Tl«e Sep.24. 4:2IPM

CITY_21MC100_011837055 NYC-WTC_000386134

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000386134Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Chain of custody form, September 2001

NYC-WTC_000232952

Chain of custody documentation for samples collected in September 2001 involving multiple New York locations and consulting firms.

Similar indexed content

Compare copies and versions →