Labor relations correspondence regarding site locations, Sep 2001

Machine-extracted title · confidence 85%

Document from the Office of Labor Relations listing various facility addresses and contact information dated September 23, 2001.

NYC-WTC_000174825–000174831
Page image
Scanned page image, NYC-WTC_000174830
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ea-24-^'®'^ ■5:33PMb associateb llc •id-845 S4B B4SBN0.1 999 P- /PQ7/19

B Adelaide Associates, LLC (including no paints or glues)..

Lead Air Sampling

Ths ambient and personnel air sampling levels set by OSHA need to be below the permissible exposure limit (PEL) of 50 micrograms per cubic meter (ug/m®). If workers are exposed to levels above this limit, certain medical surveillance monitoring, as well as appropriate engineering controls and personnel protective equipment (P.PE) are required. Several samples were above the PEL during this project.

Ambient air sampling was conducted in accordance with OSHA recommended guidelines. A persona! low volume air pump was placed In the breathing zone (4-8 feet) and the air was collected onto a 0,8 micron , 37 millimeter cassette. The cassettes were sent to a laboratory for analysis.

Asbestos Air Sampling

Air sample collection and analysis was conducted throughout the abatement project. The purpose was to document the effectiveness of the contractor’s efforts at confining asbestos to the work zone. The program included air sampling and analysis by PCM [National Institute for Occupational Safety and Health (NIOSH) Method 7400].

NIOSH Method 7400 involves the analysis of all airborne parb'culate contaminants captured on a filter medium utilizing vacuum pumps. Sampling cassettes were pre and post calibrated for flow rate in the field utilizing hand held rotometers, which in turn are calibrated against a primary standard in the laboratory. Air samples are then transmitted to the laboratory with a Chain of Custody where, after preparation, they are examined under PCM. Criteria specified for fiber counting is fiber length, length to width ratio, and morphological characteristics.

Hysitr>9Ifivu^Jgttlont/OSHA CMtpUtnetSwicu/Asii^xtaa tL^tiConsulting CommunHy HoisB Ats^ssmsni/Hutmous AbtUmeni

Jecsived SspJT 4;21PM

NYC-WTC_000174830 CITY_2IMCl0 0_013493011

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000174830Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000104673 · Box DEP Box 36

Report from Consulting & Testing Services, Inc. regarding air quality monitoring at NYU Downtown Hospital in September 2001.

Similar indexed content

Compare copies and versions →