DRAFT REV. 2/25/02

AMBIENT AIR AND DUST SAMPLING PROTOCOL

FOR

P.S.234 MANHATTAN

The New York City Board of Education (BOE) in an effort to address concerns regarding Indoor Air Quality (lAQ) and potential asbestos contamination of the ambient air at P.S. 234 Manhattan following the World Trade Center (WTC) tragedy and associated clean up work had established the following lAQ and ambient air monitoring/assessment protocol:

ASBESTOS

To address the concerns regarding the potential of asbestos contamination of the ambient air, daily air testing and analysis shall be performed, including Saturdays and Sundays, inside and outside the school building as follows:

Inside the school building

The total of 8 ambient air samples shall be collected from inside the school building each day as follows:

• First floor hallway - 2 samples (one sample from 8am-12pm & one from 12pm-4pm)

• Cafeteria - one sample during the school day

• Gymnasium - one sample during the school day

• Auditorium - one sample during the school day

• Two Classrooms facing south - 2 samples (one sample in each randomly selected classrooni immediately after the last class)

• Classroom facing east - one sample in a randomly selected classroom immediately after the last class

Outside the school building

The total of 6 ambient air samples shall be collected from outside the school building each day as follows;

• North side playground- 2 samples (one sample from 8am-12pm & one from 12pm-4pm) • West side playground- 2 samples (one sample from 8am-12pm & one from 12pm-4pm) • Roof - 2 samples (one sample from 8am-12pm & one from 12pm-4pm)

The duration of all ambient air sample shall be approximately 4 hours. The total air volume sampled at each location shall be approximately 1800 liters.

CITY_21MC100_009214610

NYC-WTC_000385787

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000385787Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →