Wipe PCB samples report, High School of Economics and Finance,

Machine-extracted title · confidence 45%

PCB wipe sample results report for BOE site in NYC, June 2002.

NYC-WTC_000384834–000384835
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

600 West Cummings Park, Suite 6! Woburn Massachusetts 01801 6: wwwatc-enviro c 781 932 9- Fax 781 932.6 ASSOCIATES INC.

June 28, 2002

Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101-4008

Re; Wipe Samples for Polychlorinated Biphenyls High School of Economics and Finance (M833) 100 Trinity Place New York, New York ATC Project No. 15-19125-0291

Dear Mr. Orlan:

ATC Associates Inc. (ATC) is pleased to provide this report of the results of the wipe samples for polychlorinated biphenyls (PCBs) collected on May 18 and 25, 2002, at the referenced location. The New York City Board of Education (BOE) requested these samples to evaluate •i possible contamination in the .school building.

SCOPE OF WORK

The samples were collected using sterile gauze pads and hexane as a solvent. The solvent was provided and samples were analyzed by PSC Analytical Services, Inc. (PSC), an American Industrial Hygiene Association-accredited laboratory in Reading, PA. The PCB analysis was performed using EPA Method 8082B.

Tenzin Namgyal, Industrial Hygienist of ATC’s New York City office, collected the samples consistent with generally accepted industrial hygiene practices. There were inherent limitations created by constraints of time, operational and work practice variability, variations in contaminant concentrations, and sampling and analytical accuracy. The results of the sampling represent conditions found on the dates the samples were collected.

WIPE SAMPLING RESULTS

ATC submitted three samples from each day to PSC for analysis. Copies of the laboratory reports are provided in the Attachment. Samples were taken from surfaces throughout the building. The sample area for each wipe sample was 100 square centimeters (lOOcm^). The areas sampled were:

• Main lobby floor; • 5th Floor Hallway by elevators; • 9th Floor Hallway by elevators.

Each sample was analyzed for seven (7) PCS compounds (see attachment).

CITY_21MC100_002882006

NYC-WTC_000384834

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000384834Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000374277

Report of PCB wipe samples collected May 18 and 25, 2002 at the school site.

Similar indexed content

NYC-WTC_000384840

PCB wipe sample results for BOE site, June–July 2002 dissemination.

Similar indexed content

NYC-WTC_000404419

ATC report of PCB wipe sample results for the BOE at 100 Trinity Place, March 2002.

Similar indexed content

Compare copies and versions →