NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 14 pages

Pace Analytical lab report, ATC project 19125-0297

Machine-extracted title · confidence 28%

PACE lab report for ATC project 19125-0297; overview of method 8290.

NYC-WTC_000383373–000383386
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Samces, Inc. 170D Elm Street Suite 200 weAnalyticar www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Minneapolis, MN 55414 Phone: 612.607.-!700 Fax: 612.607.6444

PROJECT: PCDD/PCDF ANALYSES DATE: January 9, 2002

- ISSUED TO: ATC Associates REPORT N0:01-1052540 Attn: Mr. Jim Cohn 104 East 25th Street, 10th Floor New York, NY 10010

INTRODUCTION

This report presents the results from the analyses performed on eleven samples which were ^ submitted by a representative of ATC Associates. The samples were analyzed for the presence or i J absence of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) using a modified version of USEPA Method 8290 as described below.

3 SAMPLE IDENTIFICATION n Client ID Sample Type Date Received Pace ID

ATC-1220-89M-DX1 Wipe 12/21/01 103233896 ATC-1220-89M-DX2 Wipe 12/21/01 103233904 ATC-1220-89M-DX3 Wipe 12/21/01 103233912 ATC-1220-89M-DX4 Wipe 12/21/01 103233920 ATC-1220-89M-DX5 Wipe 12/21/01 103233938 ATC-1220-89M-DX6 Wipe 12/21/01 103233946 ATC-1220-89M-DX7 Wipe 12/21/01 103233953 ATC-1220-89M-DX8 Wipe 12/21/01 103233961 . ATC-1 220-89M-DX9 Wipe 12/21/01 103233979 i ATC-1220-89M-DX10 Wipe 12/21/01 103233987 ATC-1220-89M-DX11 Wipe 12/21/01 103122995

METHODOLOGY

Sample Extractipn

, Each sample was spiked with ’®Ci2-labeled PCDD/PCDF internal standards (Table 1) and extracted ; with toluene in a Soxhlet extractor. The extract was quantitatively transferred to a Kuderna-Danish concentrator, concentrated, and solvent exchanged to hexane. The hexane extract was then j spiked with 2,3,7,8-TCDD-®^Cl4 enrichment efficiency standard (Table 1) and processed through the analyte enrichment procedures described below.

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full. without the written consent of Pace Analytical Services, Inc.

/neiac^ CITY_21MC100_002880305

NYC-WTC_000383374

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000383374Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000382417

PACE report: PCDD/PCDF levels for ATC project at 104 East 25th Street.

Similar indexed content