Pace Analytical Services, Inc.
1700 Elm Street, Suite 200
mAnaSyticar REPORT OF: CHEMICAL ANALYSES
Minneapolis, MN 55414
Phone: 612.607.1700
tifm.pacelabs.com Fax: 612.607.6444
PROJECT: PCDD/PCDF ANALYSES DATE: April 5, 2002
DSSUED TO: ATC Associates REPORT N0:02-1055017
Attn; Mr. Jim Cohn
104 East 25th Street, 10th Floor
New York, NY 10010
CMTRODUCTION
This report presents the results from the analyses performed on three samples that were submitted
by a representative of ATC Associates. The samples were analyzed for the presence or absence of
polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) using a modified version of
USEPA Method 8290 as described below.
SAMPLE IDENTIFICATION
ClientlD Sample Type Date Received Pace ID
ATC-0308-M833-DX1 Wipe 03/12/02 103384780
ATC-0308-M833-DX2 Wipe 03/12/02 103384798
ATC-0308-M833-DX3 Wipe 03/12/02 103384806
IV3ETHODOLOGY
Sample Extraction
Each sample was spiked with ’^Ci2-labeled PCDD/PCDF internal standards (Table 1) and extracted
with toluene in a Soxhlet extractor. The extract was quantitatively transferred to a Kuderna-Danish
concentrator, concentrated, and solvent exchanged to hexane. The hexane extract was then
_ spiked with 2,3,7,8-TCDD-^’Cl4 enrichment efficiency standard (Table 1) and processed through
the analyte enrichment procedures described below.
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
ndac'
CITY_21MC100_002898111