NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Air sampling for mercury, P.S. 234M, Feb 2002

Machine-extracted title · confidence 60%

Mercury vapor air sampling at PS 234M; report dated Feb 20, 2002.

NYC-WTC_000382332
Page image
Scanned page image, NYC-WTC_000382332
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 26th St

SMTC ASSOCIATES INC. Siew Yo'k. New York 10010 wwwatc- enviro.com 212353.8280 Fax 212 353 8306

February 20, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re; Air Sampling for Mercury Vapor P. S. 234M ATC Project No. 15-19125-0279

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for mercury vapor conducted on February 12, 2002, at the referenced school. The New York City Board of Education (BOE) requested this sampling at the recommendation of Environ Corp., a consultant to the parent’s association.

ATC collected four (4) samples for mercury vapor using Carulite® (Hydrar) tubes connected to battery-powered sampling pumps calibrated to collect 0.2 liters of air per minute. Samples were collected for ten (10) hours. Two (2) samples were collected indoors and two (2) were collected outdoors. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association-accredited laboratory in Reading, PA. One blank tube was also submitted. Analysis was'performed by means of a mercury analyzer according to NIOSH Method 6009. A copy of the analytical report is attached.

The sampling locations, as specified by the parent’s association consultant, were:

Main Entrance Lobby, 1“ Floor Hallway, West Playground and the Roof.

Mercury (Hg) was detected in these samples at levels that were indistinguishable from that detected in the blank.

ATC appreciates the opportunity to provide this indoor air quality service to the BOE. Please call me at (212) 353-8280 extension 212 if you have any questions.

Sincerely, ATC Associates, Inc.

James R. Cohn, CIH, CSP Regional Manager, Industrial Hygiene Division

Attachment

CITY_21MC100_002879018

NYC-WTC_000382332

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000382332Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →