NYC 9/11 Public Portal Document
ATC associates, iNC
104 E Street I (/th
New York., NV 10010
TeL 212-353-8280
Fax 212-353-8306
REPORT DATE: 02-20-02
CLIENT: WC BOE
PROJECT ADDRESS: P.S. 234M/292 Greenwich St
New York, NW 10007
PROJECT NO: 41617-0555
SAMPLED BY; Y. Efstahiou
SAMPLE DATE: 02-19-02
DATE RECEIVED: 02-19-02
DATE ANALYZED, 02-19-02
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED: Method EPA 3050/7420
ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LDvAT
(gg/ft’)
01 9679 1st Floor Hallway (Floor) <9.0 9.0
02 9679 Cafeteria (Floor) <9.0 9,0
03 9679 Gymnasium (Floor) <9.0 9.0
04 9679 Auditorium (Floor) 6834.2 9.0
05 9679 Classroom #219 (Window Sill) Facing South 11.7 7.4
06 9679 Classroom #311 (Floor) (Facing South) 520.6 9.0
07 9679 Classroom #202 (Floor) (Facing East) <9.0 9.0
08 9679 Blank <9.0 9.0
NOTE 1;
THE REPORTING LI.MIT (RL) IS 18.0 pg
NOTE 2:
HUD Guidelines for final clearance dust wipe samples: Floor 40 ng'ft/ Window sills 250 ug/fi\
Window wells 400 pg/ft’, Exterior surfaces 800 pg'ft/
CITY_21MC100_002878703
NYC-WTC_000382133
OCR can misread numbers and units. Confirm readings against the page image before using them.