NYC 9/11 Public Portal Document
ATC ASSOCIATES, INC
104 E 25th Street, 10th Floor
New York, NY 10010
Tel. 212-353-8280
Fax 212-353-8306
REPORT DATE: 02-06-02
CLIENT; NYC BOE
PROJECT ADDRESS: PS 234M
292 Greenwich Street, NY, NY 10007
PROJECT NO: 41617-0555
SAMPLED BY: Y.Efstathiou
SAMPLE DATE: 02-05-02
DATE RECED ED: 02-05-02
DATE ANALYZED: 02-05-02
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED: Method EPA 3050/7420
ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION-
ID NO. CONCENTRATION LIMIT
01 9659 1 St Floor Hallway Floor <9.0 9.0
02 9659 Cafeteria Floor <9.0 9.0
03 9659 Gymnasium Floor <9.0 9.0
04 9659 Auditorium <9.0 9.0
05 9659 Classroom #311 Floor (Facing South) <9.0 9.0
06 9659 Classroom #211 Window Sill (Facing South) <7.6 7.6
07 9659 Classroom #302 Floor (Facing East) 9.8 9.0
08 9659 Field Blank <9.0 9.0
NOTEl:
THE REPORTING LIMIT (RL) IS 18.0 pg
NOTE 2;
HUD Guidelines for final clearance dust wipe samples: Floor 40 pg/ft’, Window sills 250 pg'fl\
Window wells 400 pg/ft/ Exterior surfaces 800 pg/ft/
CITY_21MC100_002878673