NYC-WTC_000379405
TEM analysis results for air samples at New Stuyvesant HS exterior/interior, Jan 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis results for air samples collected at the site.
NYC-WTC_000380647–000380649OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Associates 104 East 25 Street, New York, NY 10010 Phone: (212) 353-8280 Fax:(212) 353-8306 Orc Attn: Ml. Bernard Orlan Received; 1/29/02 6:00:00 PM N.Y.C. Board of Education 28-11 Queens Plaza North ATC Group#: 6501 Long Island City, NY 11101 Analysis Date; 1/30/02 Fax: (212)475-4122 Phone:' (212)477-8941
Project: New Stuyvesant H. S., 345 Chambers St., NY , NY Exterior and' Interior of Building and Roof
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Aren Non -Asbestos Structures Sensitivity ■ Concentration Sample , Volume Analyzed Asb Type(s) O.Su-S (S/cc) (S/mm^) (S/cc) Notes 1 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6501 -1
2 1936.00 0.0450 0 None Detected O ' 0 0.0044 <22.24 '<0.0044 6501 -2
.3 1944.00 0.0450 0 None Detected 0 0. . 0.0044 <22.24 <0.0044 6501 -3
4 1944.00 '0.0450 ' 0 NoneDetected 0 0 0.0044 <22.24 <0.0044 6501 -4
5 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6501 -5
6 1952.00 0.0450 0 NoneDetected 0 0 0.0044 <22.24 <0:0044 6501 -6
7 1952.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6501 -7
8 1952.00 0.0450 0 NoneDetected 0 0 0.0044 <22.24 <0.0044 6501 -8
ROMAN PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed by: . Approved by;
Disclaimer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible for data reported in structures/mm’. This report may not be reproduced, except in.full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 96% confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
i, Accredited for NVLAP PLM/TEM #101187-0, NY State ELAP #10879 I
CITY_21MC100_002876633
NYC-WTC_000380647
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000379405
TEM analysis results for air samples at New Stuyvesant HS exterior/interior, Jan 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000379315
TEM asbestos analysis results for 6293, New Stuyvesant HS, Jan 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380676
TEM asbestos analysis results for exterior/interior of New Stuyvesant High School building.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398728
TEM asbestos analysis of exterior/interior air at New Stuyvesant HS, Dec 17, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000410726
TEM asbestos analysis results for air samples at New Stuyvesant H.S., exterior/interior, 01/27/02.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398774
Asbestos TEM analysis of air samples for New Stuyvesant High School, Dec 24, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000378888
TEM analytical data sheet for air samples at New Stuyvesant High School; includes sample 9/10 details.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380715
TEM analysis results for exterior/interior air samples at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380765
TEM analysis data and documentation for Stuyvesant High School samples, Feb 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398754
AHERA TEM asbestos analysis of exterior/interior building samples for New Stuyvesant High School, Dec 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000379743
TEM analysis of air samples at New Stuyvesant High School, Feb 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000225516
Analytical data log from ATC Associates recording fiber analysis results for New Stuyvesant High School samples received December 13, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000190835
Comprehensive laboratory report from ATC Associates detailing exterior and interior building fiber analysis performed for the NYC Board of Education on April 28, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000379656
TEM fiber analysis for AHERA at New Stuyvesant High School building exterior/interior, Feb 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000271519
TEM asbestos analysis results for exterior/interior building areas at New Stuyvesant HS.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380580
TEM asbestos analysis results for NYC BOE project at New Stuyvesant High School, Jan 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000271833
TEM asbestos data for air samples at New Stuyvesant High School, Nov 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000378571
TEM asbestos analysis with AHERA methodology for exterior/interior samples.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM analysis results for air samples at New Stuyvesant HS exterior/interior, Jan 2002.
Similar indexed content
NYC-WTC_000379315
TEM asbestos analysis results for 6293, New Stuyvesant HS, Jan 2002.
Similar indexed content
TEM asbestos analysis results for exterior/interior of New Stuyvesant High School building.
Similar indexed content
TEM asbestos analysis of exterior/interior air at New Stuyvesant HS, Dec 17, 2001.
Similar indexed content
TEM asbestos analysis results for air samples at New Stuyvesant H.S., exterior/interior, 01/27/02.
Similar indexed content