ATC Associates 104 East 25 Street, New York, NY 10010 Phone: (212) 353-8280 Fax; (212) 353-8306 (Sot Attn: Mr. Bernard Orlan Received: 3/4/02 9:00:00 PM N.Y.C. Board of Education ATC Group #: 6934 28-11 Queens Plaza North Analysis Date: 3/5/02 Long Island City, NY 11101

■Fax;“(212) 475-4122 " * Phone:—12172) 477-8941

Project: New Stuyvesant H. S. , 345 Chambers St.. NY . N Exterior and Interior of Building and Roof

Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Axhexiox Area Nun Asbestos It Stractares Sensitivity Cuncenlratiiin Sample f''olame Analyzed Asb Type(s) 0.5f,-5 5,, (S/cc) (S/mni-) (S/cc) Nulex

I 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <11.0045 6934 -I

2 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 6934 -2

J 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 6934 -3

4 192S.00 U.0450 0 None Detected 0 0 0.0044 <0.0044 6934 -4

5 192S.O0 0.0450 0 None Detected I.) 0 0.(1044 <0.0044 6934 -5

6 1936.00 0.0450 0 None Detected 0 0 0.0044 <0.01144 6934 -6

7 1936.00 • 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6934 -7

S 1936.00 0.0450 0 None Delected 0 0 0.0044 <22.24 <11.01)44 6934 -S

ROMAN PEYSAKHOV MICHAEL A. CORYCKI, Ph.D.

Analyzed by: tppioved by:

Disclaimer: The laboratory is not responsible lor data reponed in stfuctures/cc. which is dependent on volume collected by non-laboraiory personnel. This labwmiy responsible lor data reported in structures/mm’ This report may not be reproduced, except in full, without written approval by ATC Associates Inc This report may not be used to claim product endorsement by NVLA.° or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request.

Accredited for NdLAP PLM/TEM #101187-0, NY State ELAP #10879

CITY_21MC100_002875973

NYC-WTC_000380409

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000380409Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000398591

TEM analysis results for exterior/interior air samples at New Stuyvesant High School.

Similar indexed content

NYC-WTC_000380784

TEM asbestos analytical data and bench sheets attached for Stuyvesant HS.

Similar indexed content

NYC-WTC_000253898

N.Y.C. BOE project for exterior/interior asbestos analysis by TEM under AHERA at New Stuyvesant H.S.

Similar indexed content

NYC-WTC_000349554

TEM asbestos analysis results; AHERA-compliant, New Stuyvesant HS, May 2002.

Similar indexed content

NYC-WTC_000410879

TEM analysis documentation for exterior/interior samples at New Stuyvesant HS, Feb 2002.

Similar indexed content

Compare copies and versions →