NYC-WTC_000410860
TEM asbestos analysis report for exterior/interior building samples at New Stuyvesant HS, Feb 2002.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗TEM asbestos fiber analysis of air samples from New Stuyvesant High School, Feb 2002.
NYC-WTC_000380099–000380101OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Associates 104 East 25 Street, New York, NY 10010 Phone: (212)353-8280 Fax: (212) 353-8306 ITC Attn: Mr. Bernard Orlan Received: 2/20/02 6:00:00 PM N.Y.C. Board of Education ATC Group#: 6766 28-11 Queens Pla2a North Analysis Date: 2/22/02 Long Island City, NY 11101 Fax; (212)475-4122 Phone: (212)477-8941 Project; New Stuyvesant H. S., 345 Chambers St., NY , NY Exterior and Interior of Building and Roof
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample Volume Analyzed Asb Type(s) O.Sp-S 5p (S/CC) (S/mm^) (S/cc) Notes
1 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6766-I
2 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 • 6766 -2
3 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6766 -3
4 1936,00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6766 -4
5 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6766 -5
6 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6766 -6
7 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6766 -7
8 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6766 -8
MARK PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed by: Approved by:
Disclaimer The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible for data reported in structures/mmt This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request
Accredited for NVLAP PLMAEM #101187-0, NY State ELAP #10879
CITY_2IMC10 0_0 0 28 7 5 6 2 5
NYC-WTC_000380099
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000410860
TEM asbestos analysis report for exterior/interior building samples at New Stuyvesant HS, Feb 2002.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000216423
ATC Associates report on asbestos fiber analysis of exterior and interior building samples from New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380041
Asbestos TEM analysis results for New Stuyvesant H.S., Feb 2002.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380070
TEM asbestos analysis of exterior and interior building air samples at New Stuyvesant High School, Feb 2002.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380784
TEM asbestos analytical data and bench sheets attached for Stuyvesant HS.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380504
TEM asbestos analysis results for exterior/interior building samples at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000253898
N.Y.C. BOE project for exterior/interior asbestos analysis by TEM under AHERA at New Stuyvesant H.S.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273218
TEM asbestos analysis results for exterior/interior areas at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380355
TEM asbestos analysis report for external/interior building samples, Mar 3, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380469
TEM asbestos analysis with lab results and AHERA methodology notes.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398852
Lab TEM asbestos analysis results with sample details for DOE project.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349454
TEM asbestos analysis per AHERA; includes concentration data for samples.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000398473
TEM asbestos analysis report for New Stuyvesant H.S. building, Mar 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380041
Asbestos TEM analysis results for New Stuyvesant H.S., Feb 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261937
TEM analysis results of air samples from New Stuyvesant High School exterior/interior areas.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380469
TEM asbestos analysis with lab results and AHERA methodology notes.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261966
TEM analysis results of air samples from New Stuyvesant High School exterior/interior areas.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398852
Lab TEM asbestos analysis results with sample details for DOE project.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis report for exterior/interior building samples at New Stuyvesant HS, Feb 2002.
Similar indexed content
ATC Associates report on asbestos fiber analysis of exterior and interior building samples from New Stuyvesant High School.
Similar indexed content
Asbestos TEM analysis results for New Stuyvesant H.S., Feb 2002.
Similar indexed content
TEM asbestos analysis of exterior and interior building air samples at New Stuyvesant High School, Feb 2002.
Similar indexed content
TEM asbestos analytical data and bench sheets attached for Stuyvesant HS.
Similar indexed content