Analytical report, hydrocarbons, ATC 19125-0290

Machine-extracted title · confidence 52%

Analytical report for hydrocarbons under ATC WorkOrder 19125-0290.

NYC-WTC_000376852–000376857
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

J^n 07 02 Oe:O0p PSC Analytical Services G109219GG7 P-7

page 6 of 6 07JAN02_1746_I3_N1261_RFR

INDUSTRIAL HYGIENE ENVIRONMENTAL TESTING • EPA/NVLAP 101262-0 • NY DOH 10903 • NJ DEP 77678 . AIHA ACCREDITATION NO. 100439 • PA DER 06-353 . CT DPH PH-0238 . NC DENR 599

Project: 209192 RESULT UNITS CONCENTRATION UNITS METHOD

ATC-1229-894M-VOC1Q Air Volume: 0 L Lab Sample: 1475609

Pentane < 0.020 mg/sample 1500 Acetone <.0,020 mg/sample 1300 Methylene chloride < 0.020 mg/sample 1005 Hexane < 0.020 mg/sample 1500 Chloroform < 0.020 mg/sample 1003 Methyl chloroform < 0.020 mg/sample 1003 total other A Hydrocarbons < 0.020 mg/sample 1500 Benzene < 0.020 mg/sample 1501 1,2-Dichloroethane < 0.020 mg/sample 1003 Trichloroethylene < 0.020 mg/sampl'e 1022 Toluene < 0.020 mg/sample 1501 PCE (Tetrochloroefhene) < 0.020 mg/sample 1003 Chlorobenzene < 0.020 mg/sample 1003 Ethylbenzene < 0.020 mg/sample 1501 Styrene < 0.020 mg/sample 1501 Cumene (Isopropylbenzene) < 0.020 mg/sample ■1501 Xylenes, Total < 0.020 mg/sample 1501 total other B Hydrocarbons < 0.020 mg/sample 1501

final sample concentrations calculated from air volumes supplied on chain of custody. < Indicates less than the limit of quantitation.

CITY_21MC100_002854457

NYC-WTC_000376857

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000376857Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →