Analytical report, ATC work order 209192

Machine-extracted title · confidence 42%

ATC analytical results for hydrocarbons in school sample set, Jan 2002.

NYC-WTC_000297613–000297618
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Jan 07 02 OGsOSp PSC Rnalytical Services B109219GG7 P-7

page 6 of 6 07JAN02_1746_!3_(l1261_RFR

INDUSTRIAL HYGIENE ENVIRONMENTAL TESTING . EPA/NVLAP 101262-0 ■ NY DOH 10903 . NJ DEP 77678 . AIHA ACCREDITATION NO 100439 . PA DER 06-353 . CT DPH PH-0238 crats—zt' - -t. .tt ,-i . NC DENR 599

Project: 209192 RESULT UNITS CONCENTRATION UNTTS METHOD

ATC-1229-894M-VOC10 Air Volume: 0 L Lab Sample’ 1475609

Pentane < 0.020 mg/sa triple 1500 Acetone < 0.020 mg/sample 1300 Methylene chloride < 0.020 mg/sample 1005 Hexane < 0.020 mg/sample 1500 Chloroform < 0.020 mg/sample 1003 Methyl chloroform < 0.020 mg/sample 1003 total other A Hydrocarbons < 0.020 mg/sample 1500 Benzene < 0.020 mg/sample 1501 1,2-Dichloroethane < 0.020 mg/sample 1003 Trichloroethylene < 0.020 mg/sample 1022 Toluene < 0.020 mg/sampie 1501 PCE (Tetrachloroethene) < 0.020 mg/sample 1003 Chlorobenzene < 0.020 mg/sample 1003 Ethylbenzene < 0.020 mg/sample 1501 Styrene < 0.020 mg/sample 1501 Cumene (Isopropylbenzene) < 0.020 mg/sample 1501 Xylenes, Total < 0.020 mg/sample 1501 total other B Hydrocarbons < 0.020 mg/sample 1501

Final sample concentrations calculated from air volumes supplied on chain of custody. < Indicates less than the limit of quantitation.

I CITY_21MC100_006797665

NYC-WTC_000297618

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000297618Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →