NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Air metals sampling letter, HS for Leadership, 2002

Machine-extracted title · confidence 41%

Letter reporting air metals sampling conducted for HS for Leadership project.

NYC-WTC_000376762–000376763
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St New York. New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

February 21, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education . 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Metals High School for Leadership & Public Service (M894) ATC Project No. 15-19125-0290

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for metals conducted on February 8, 2002, at the referenced school. The New York City Board of Education (BOE) requested these samples to determine if acceptable air quality is being maintained.

ATC collected four (4) samples for metals in air. Samples were collected for a minimum of ten (10) hours. Three (3) samples were collected inside the building and one (1) was collected outdoors. One blank filter was also submitted. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association-accredited laboratory in Reading, PA. Copies of the analytical reports are attached.

The samples were collected using 37 mm mixed cellulose ester filters connected to battery- powered sampling pumps at a flow rate of 2 liters per minute. Pumps were calibrated before and after each sampling period. Analysis was performed by NIOSH Methods 7300M. Each sample was analyzed for a panel of eleven (11) metals. The metals were aluminum (Al), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), magnesium (Mg), manganese (Mn), molybdenum (Mo), nickel (Ni) and zinc (Zn^

The locations of the samples were the Roof by air intake, floor Main Lobby, 5® floor Hallway near the elevator and the 10* floor Hallway near the elevator.

The established regulatory values for metals are intended for industrial workplace exposures and are not generally applicable to office/school settings. There are no standards for these materials in indoor air in non-industrial situations.

AIR SAMPLE RESULTS

Metals were not found above the limits of detection in any of the samples. Chromium was detected in the blank. It has typically been detected as a trace contaminant of the filters.

CITY_21MC100_002854350

NYC-WTC_000376762

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000376762Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000239983

Letter from ATC Associates reporting air sampling for metals conducted at the school in February 2002.

Similar indexed content

NYC-WTC_000239974

Letter from ATC Associates reporting air sampling for metals conducted at the school in February 2002.

Similar indexed content

Compare copies and versions →