i04 East 25tt’ St , 10th Flooi New York, New York 100'0 WWW atc-enviro com 212 353 8280 Fax 212 353 8306 ASSOCIATES INC.

April 10, 2002

Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101-4008

Re: Indoor Air Quality Assessment P.S. ISOM 334 Greenwich Street New York, New York 10013 ATC Project No. 15-19125-0289

Dear Mr. Orlan;

ATC Associates Inc. (ATC) is pleased to provide this report of indoor air quality (lAQ) measurements collected on April 9, 2002, at the referenced school. The New York City Board of Education (BOE) requested these measurements to evaluate air quality in the school building prior to re-occupancy.

SCOPE OF WOE<K

ATC conducted this evaluation to assess the basic parameters of temperature, relative humidity. carbon dioxide (CO,) and carbon monoxide (CO).

ATC measured temperature, relative humidity, CO, and CO with a Q-Trak® Mode! 8551. manufactured by TSI, Inc.

ATC measured concentrations of respirable particulates (PM2.5) with a Dust-Trak®^ Aerosol Monitor Model 8520, manufactured by TSI, Inc.

ATC measured concentrations of Total Volatile Organic Compounds (TVOCs) using a R.AE Systems, Inc. MiniRAE® photoionization detector (PID).

Mr. Kevin Fitzpatrick, Environmental Technician, of ATC’s New York City office, conducted the assessment.

ATC’s findings and conclusions are based on a visual inspection, real-time environmental measurements and conditions present in the school at the time of the assessment.

CITY_21MC100_003755317

NYC-WTC_000374656

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000374656Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000375441

Indoor air quality measurements at P.S. 150M, school building prior to re-occupancy.

Similar indexed content

Compare copies and versions →