Air sampling letter, P.S. 234M, Dec 2001

Machine-extracted title · confidence 28%

ATC Associates letter reporting hydrogen cyanide air sampling at P.S. 234M, December 2001.

NYC-WTC_000373490–000373491
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

(Satc ASSOCIATES INC. 104 East 25th Street New York. New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306

January 8, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Cyanide P. S. 234M ATC Project No. 15-19125-0279

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for hydrogen' cyanide (HCN) conducted on December 11, 2001, at the referenced school. The New York City Board of Education (BOE) requested this sampling at the recommendation of Environ Corp., a consultant to the parents association. '

On both days, ATC collected two (2) samples for HCN using soda lime tubes connected to battery-powered sampling pumps calibrated to collect 0.2 liters of air per minute. One sample was collected in the rear playground/courtyard and one was collected on the roof near the air intake.' Samples for HCN were not collected inside the school. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association-accredited laboratory in Reading, PA. One blank tube was also submitted. Analysis was performed by modified NIOSH Method 7904. A copy of the analytical report is attached.

- HCN was detected at levels above the concentration found in the blank as shown in Table 1. Airborne HCN Concentrations December 11, 2001 HCN per sample HCN Cone. HCNyConc. <, Sample Location 1 (micrograms), ' (mg/m )* ’ ; (Blank ■ 1 , corrected) ' Rear Playground 0.26 120 0.0022 0.0008

Roof by air intake 0.74 120 0.0062 0.0048

Blank 0.16

* milligrams per cubic meter of air

CITY_2IMCl0 0_0 00462176 NYC-WTC_000373490

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000373490Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →