Mr. Bernard P. Orlan April 23, 2002 Indoor Air Quality Measurements Page 3 Stuvvesant High School (M477) ATC Project No. 15-19125-0246 Real-Time Environmental Measurements
ATC collected one hundred and twenty (120) sets of real-time environmental measurements consisting of one hundred and eighteen (118) in the school building and two (2) outdoors. All ten floors of the school were surveyed. These results are described below.
Field data sheets are found in Attachment 1. Readings began at 7:50 A.M. and concluded after ' 1:10 P.M,
Temperature
Indoor dry bulb temperature measurements ranged from 65.6 °F to 74.5 °F. Fifty (50) of the measurements for indoor temperature were below and sixty-eight (68) measurements were within the range of 73 to 79°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during summer conditions. The outdoor temperature range was 59 to 59.6 °F.
Relative Humidity
The relative humidity indoors ranged from 32 percent to 45.5 percent. All of the indoor measurements for relative humidity were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity levels were 47.8 and 53.9 percent.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 424 ppm to 1244 ppm. Twenty-three (23) measurements were above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (background) CO2 concentrations were 416 and 451 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1151 ppm (background level + 700 ppm). The highest concentration (1244 ppm) was measured in room 1007 at 12:50 PM with 30 occupants. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors ranged from 0 ppm to 1 ppm. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentrations ranged from 0 ppm to I ppm.
Respirable Particulates (PM2^^)
Respirable particulate concentrations* indoors ranged between 2 pg/m3 to 18 pg/m^ with an average of approximately 12 ug/m^. All of the indoor measurements for PM2.5 were below' the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and the USEPA recommendation of 40 pg/m^ for sensitive individuals and children. The outdoor respirable particulate concentrations were 14 and 45 pg/m^.
CITY_21MC100_002868242
NYC-WTC_000372758
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000406604
April 23, 2002 memo describing IAQ measurements at Stuyvesant High School.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000373022
ATC IAQ report for Stuyvesant High School dated May 31, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000213095
Cover letter and report from ATC Associates detailing indoor air quality measurements collected at Stuyvesant High School on May 28, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000372774
IAQ measurements collected at Stuyvesant High School on April 23, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000372973
ATC IAQ measurements collected on May 23, 2002 for Stuyvesant High School.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000372945
ATC IAQ measurements collected on May 15, 2002 at Stuyvesant High School.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000213072
Cover letter and report from ATC Associates detailing indoor air quality measurements collected at Stuyvesant High School on May 16, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000406861
May 28, 2002 IAQ report for Stuyvesant High School under ATC project 15-19125-0246.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000213077
Cover letter and report from ATC Associates detailing indoor air quality measurements collected at Stuyvesant High School on May 20, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000336258
ATC reports IAQ measurements collected at Stuyvesant High School on Apr 22, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000406883
May 30, 2002 IAQ measurements at Stuyvesant High School for Board of Education.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000406878
May 29, 2002 IAQ measurements at Stuyvesant High School.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000336429
BoE IAQ measurements at Stuyvesant HS; March 12–13, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000213072
Cover letter and report from ATC Associates detailing indoor air quality measurements collected at Stuyvesant High School on May 16, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000336395
ATC IAQ measurements collected March 8–12, 2002 at Stuyvesant HS.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000255885
ATC IAQ measurement report for Stuyvesant High School dated January 18, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270026
ATC IAQ measurements conducted March 15, 2002 at Stuyvesant High School for NYC BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000336353
ATC provides IAQ measurements at Stuyvesant High School for BOE evaluation, March 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000406604
April 23, 2002 memo describing IAQ measurements at Stuyvesant High School.
Similar indexed content
NYC-WTC_000373022
ATC IAQ report for Stuyvesant High School dated May 31, 2002.
Similar indexed content
Cover letter and report from ATC Associates detailing indoor air quality measurements collected at Stuyvesant High School on May 28, 2002.
Similar indexed content
NYC-WTC_000372774
IAQ measurements collected at Stuyvesant High School on April 23, 2002.
Similar indexed content
NYC-WTC_000372973
ATC IAQ measurements collected on May 23, 2002 for Stuyvesant High School.
Similar indexed content