1700 Err Streei - Sure 2C0
Minneapolis, MN 55414
weAnalvticar_________ Method 8290 Analysis Results
Tel: 512-607-: TOC
Fox-
Client - ATC
Client’s Sample ID ATC-0427-STY-DX10
Lab Sample ID 103513562
Filename U20529A_13
Injected By CVS
Total Amount Extracted 0.79 g Matrix DUST
% Moisture NA Dilution NA
Dry Weignt Extracted NA Collected 04/27/2002
ICAL Date 04/16/2002 Received 05/01/2002
CCal Filenams(s5 U20528B_04 & U20529A_16 Extracted 05/21/2002
Method Blank ID BLANK-1634 Analyzed 05/29/2002 19:21
Native Cone EMPC LRL Internal ng’s Percent
Isomers ng/Kg ng/Kg ng/Kg Standards Added Recovery
2,3,7.8-TCDF 70 2.50 E 2,3,7,8-TCDF-13C 2.00 59
Total TCDF 1000.0 2.50 2,3,7,8-TCDD-13C 2.00 65
1.2,3,7,8-PeCDF-l3C 2.00 58
2,3.7,8-TCDD 8.9 2.70 JA 2,3,4,7,8-PeCDF-13C 2.00 60
Total TCDD 2400.0 2.50 1.2,3,7,a-PeCDD-13C 2.00 67
1,2,3,4,7,8-HxCDF-13C 2.00 74
1,2,3,7,8-PeCDF S4 13.00 E 1,2.3,6,7,8-HxCDF-l3C 2.00 79
2,3,4.7,8-PeCDF 100.0 13.00 2,3.4.6.7,8-HxCDF-13C 2.00 78
Total PeCDF 640.0 13.00 1.2,3,7,8,9-HxCDF-13C 2.00 83
1,2.3.4.7,8-HXCDD-13C 2.00 78
1,2,3,7,8-PeCDD 39.0 13.00 J 1.2,3,6,7,8-HxCDD-13C 2.00 76
Total PeCDD 1800.0 13.00 1,2,3,4,6,7,8-HpCDF-13C 2.00 82
1.2,3,4,7.8,9-HpCDF-l3C 2.00 87
1,2,3,4,7,8-HxCDF 55.0 13.00 J 1,2,3.4.6,7,8-HpCDD-13C 2.00 101
1,2.3,6,7,8-HxCDF no 13.00 E OCDD-13C 4.00 88
2.3,4,6,7.8-HxCDF 89.0 13.00
1,2,3.7,8,9-HxCDF 14.0 13.00 J 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF 610.0 13.00 1,2,3.7,8,9-HXCDD-13C 2.00 NA
1.2,3,4,7,8-HxCDD 43.0 13.00 J 2,3,7,8-TCDD-37CI4 0.20 71
1,2,3,6.7,8-HxCDD 68.0 13.00
1.2,3,7,8,9-HxCDD 51.0 13.00 J
Total HxCDD 2000,0 13.00
1,2,3,4,6,7,8-HpCDF 360.0 13,00 Total 2,3.7.8-TCDD
1,2,3,4,7,a.9-HpCDF ND 26.00 A Equivalence: 120 ng/Kg
Total HpCDF 360.0 13,00 (Using ITE Factors)
1,2,3,4,6,7,a-HpCDD 550.0 13.00
Total HpCDD 1100.0 13.00
OCDF 340.0 25.00
OCDO 3600,0 25.00
Results reported on a total weight basis LRL = Lower Reponing Limit
Cone a Concentration (Totals include 2,3,7.8-subfitituted isomers) I = Interference
EMPC * estimated Maximum Possible Concentration E » PCDE Intorterenca
A = Detection Llmli based on signai-to-noiso measurement S 3 Saturated signal
J 3 Concentration detected Is below the calibration range ND = Not Detected
B = Loss than 10 times higher than method blank level NA = Not AppiicaDle
P s Recovery outside ot target range NC = Not Calculated
Nn a Value obtained from additional analysis • a See Discussion
Report No.... 02-1057132
REPORT OF LABORATORY ANALYSIS
This report snail not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_002868034
NYC-WTC_000372630